Coupled amidolytic assay for factor VII: its use with a clotting assay to determine the activity state of factor VII

Author:

Seligsohn U,Osterud B,Rapaport SI

Abstract

Abstract A coupled amidolytic assay for factor VII (VII) has been developed that when used with a clotting assay for VII enables detection of activated VII. In the assay, VII in a test material determines generation of factor Xa in a mixture of purified factor X, tissue factor, and calcium; factor Xa is measured with a chromogenic substrate. Factor VII activity in the coupled amidolytic assay (VIIam) correlated well with VII activity in a one-stage clotting assay (VIIc) in 57 healthy subjects, 5 patients with hereditary VII deficiency, and 11 patients with liver disease. Activation of plasma VII by kaolin, clotting, or cold strikingly increased VIIc but not VIIam levels. Thus the ratio VIIc/VIIam (VII activity ratio) is a measure of VII activation. In 27 warfarin-treated patients the mean VII activity ratio was significantly decreased, reflecting a greater decline in VIIc than in VIIam. This probably stems from partially carboxylated VII being able to act during the 3-min incubation of the amidolytic assay but unable to act rapidly enough to affect the clotting assay. Measurement of VIIc/VIIam should enable evaluation of the activity state of VII in thrombotic disorders and in components for transfusion therapy.

Publisher

American Society of Hematology

Subject

Cell Biology,Hematology,Immunology,Biochemistry

Cited by 69 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Uri Seligsohn, MD (1937–2022);Journal of Thrombosis and Haemostasis;2022-05

2. Bile acids and coagulation factors;European Journal of Gastroenterology & Hepatology;2013-02

3. Clotting Factors and Inhibitors: Assays and Interpretation;Laboratory Hematology Practice;2012-08-08

4. Activation of 125I-Factor IX and 125I-Factor X: Effect of Tissue Factor and Factor VII, Factor Xa and Thrombin;Scandinavian Journal of Haematology;2009-04-24

5. Oral anticoagulant control with a chromogenic substrate: calibration, precision and cost;Clinical & Laboratory Haematology;2008-06-28