STANDARDIZATION OF THE QUICK PROTHROMBIN TEST

Author:

AGGELER PAUL M.1,HOWARD JOAN1,LUCIA S. P.1,CLARK WILLIAM1,ASTAFF ALEXIS1

Affiliation:

1. Division of Preventive Medicine, University of California Medical School, San Francisco.

Abstract

Abstract A large specimen of human brain, obtained at autopsy, was dehydrated and stored in an evacuated desiccator. Portions of the material were removed when needed and the desiccator was re-evacuated. Under these conditions there was no loss of thromboplastic potency over a period of two years. See PDF for Table See PDF for Table The dry oxalate mixture (6 mg. of ammonium oxalate and 4 mg. of potassium oxalate) was used as an anticoagulant in order to obtain plasma for the prothrombin tests. With the specimen of thromboplastin used in these experiments, normal standards for the Quick prothrombin test were found as shown in table 8. These results do not necessarily mean that the normal range of prothrombin concentrations is from 75 to 140 per cent of the actual amount of prothrombin in the plasma of the average normal subject. They mean only that with the methods here employed, values within this range may be expected to occur. There was no significant difference between the prothrombin values obtained in a group of normal subjects by methods using diluted or undiluted plasma. In repeated tests on the same subject there appeared to be slightly greater accuracy when the tests were performed on diluted plasma, but there was no significant difference between the results obtained with plasma diluted to 50 or to 25 per cent of its original concentration. Repeated tests on diluted and undiluted plasma from the same normal subject produced the range of normal variation about the various prothrombin concentrations shown in table 9. The normal variation that may be expected to occur at any given prothrombin level must be considered in interpreting the variations that appear after administration of vitamin K or dicumarol. The use of a single specimen of blood from one random normal subject as a normal standard may lead to considerable error, because of unavoidable technical variables and because of differences in the prothrombin concentrations of different normal subjects. To establish reliable normal standards, the blood of at least 5 normal subjects should be individually tested with the same specimen of thromboplastin and the results averaged.

Publisher

American Society of Hematology

Subject

Cell Biology,Hematology,Immunology,Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3