Abstract

Abstract Background: Terumo BCT recently offered a new method of peripheral blood stem cell (PBSC) collection using the Spectra Optia¨, an apheresis instrument. The new protocol includes a continuous mononuclear cell collection (CMNC) as opposed to an older version, the mononuclear cell collection (MNC), which involves an additional step where product pools through a cell separation insert. Our institution has used both methods and the purpose of this study was to compare the CMNC to the MNC protocol, including run times and PBSC product characteristics. Methods: A retrospective review and comparison of parameters from 120 collection procedures using the MNC insert and 60 collection procedures using the CMNC insert was done using the t-test. Data from patients/donors (including 20 allogeneic donors) as well as procedure details including run time, flow cytometry marker for stem cells (CD34)-positive (CD34+) throughput, CD34+ collection efficiency (CE%), platelet loss (plt loss/total blood volume [TBV]), and collection product characteristics were included in the analysis. Results: The MNC donor group included 12 allogeneic donors, which is comparable to the 8 allogeneic donors in the CMNC group. Donor weight and patient weight was not significantly different between the two groups. Pre-procedure laboratory values (WBC, percentage of lymphocytes [lymph%], percentage of monocytes [MNC%], and platelet count) were also similar between the two groups. Run time was found to be significantly shorter using the CMNC protocol compared to the MNC protocol. Product volume was also significantly lower in the CMNC group compared to the MNC group. Although the volume was lower, the CMNC product had significantly higher white blood cell count (WBC), MNC%, and lymph% when compared to the MNC product. The CD34+ throughput was significantly higher in the CMNC group than the MNC group. The CD34+ CE% was found to be slightly increased in the CMNC group, though not significantly. The platelet loss was nearly identical in both protocols when normalized for total blood volume. Product hematocrit (HCT%) was significantly higher using the CMNC protocol; however, the red blood cell volume never exceeded 20 mL due to the lower product volume with the CMNC protocol. The numerical results are summarized in the Table. Conclusion: The CMNC protocol collects a smaller volume of a purer product when compared to the MNC protocol with comparable platelet and red blood cell loss. Staff members who perform apheresis procedures are pleased by the shorter run time. Table Table. Disclosures Roig: Terumo BCT: Employment.

Publisher

American Society of Hematology

Subject

Cell Biology,Hematology,Immunology,Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3