A Comparison of IEF and MSMS for Clinical Hemoglobinopathy Screening in 40,000 Newborns

Author:

Daniel Yvonne1,Turner Charles2,Farrar Lisa3,Dalton R. Neil4

Affiliation:

1. Blood Sciences, Guy’s & St Thomas’ NHS Foundation Trust, London, United Kingdom

2. WellChild Laboratory, Guy’s & St Thomas’ NHS Foundation Trust, London, United Kingdom

3. Haematology, St James University Hospital, Leeds, United Kingdom

4. WellChild Laboratory, King’s College London, London, United Kingdom

Abstract

Abstract Currently, newborn haemoglobinopathy screening is carried out using HPLC or isoelectric focusing (IEF). We have previously described a rapid and specific electrospray mass spectrometry–mass spectrometry (MSMS) technique, using multiple reaction monitoring (MRM) based peptide analysis, for simultaneous detection of the clinically significant haemoglobinpathies; haemoglobin (Hb)S, HbC, HbE, HbDPunjab and HbOArab. Here we report the results of a comparison of 40,000 newborn blood spots screened by both IEF and MSMS. For both IEF and MSMS analysis, blood spots (3.2mm) were punched into separate 96 well plates. IEF was performed using the Resolve haemoglobin test kit (PerkinElmer Life Sciences, Waltham, USA) and Isoscan imaging system. For MSMS analysis, the blood spots were digested for 30min at 37°C with a trypsin reagent, and diluted in mobile phase (acetonitrile: water, 50:50, with 0.025% formic acid. Sample, 2μl, was injected directly into the mobile phase (flow rate 80μl/min) and analysed, in positive ion mode, using a Sciex API4000 (Applied Biosystems, Warrington, UK). Specific MRM transitions for HbS, HbC, HbE, HbDPunjab, HbOArab, normal beta, alpha, gamma and delta chains were acquired; total acquisition time per sample was 60 sec. This enabled identification of sickling disorders and thalassaemia major, as well as assessment of transfusion state and potential identification of HbLepore and HbBarts. 40,000 blood spot samples for routine newborn haemoglobinopathy screening were analysed in parallel. HbS was detected in 199 samples; 8 were HbS/HbF only and 3 HbSC. HbC was detected in 39 samples, HbDPunjab in 52, HbE in 48. No HbOArab or HbLepore mutations were detected by either method. There have been no discrepancies between the analytical techniques. Using MSMS, mutation positive samples can be re-run in product ion scan mode to provide peptide sequence and hence unequivocal confirmation of the haemoglobin variant. In addition, 5,000 samples were analysed on a Sciex API4000 Q trap; using the information dependent acquisition facility provided “real time” peptide sequencing thus removing the requirement for re-injection. Sample preparation is very quick and simple for both methods, but the consumable costs associated with the MSMS technique are <10% of those for IEF. The capital cost of MSMS can be offset by high throughput and/or integration with current inherited metabolic disease screening by MSMS. The specificity of the MSMS analysis implies that haemoglobinopathy detection can be limited to specified conditions, based on agreed screening policy, and can eliminate the need for costly and time consuming second line testing. This study demonstrates that newborn haemoglobinopathy screening can be carried out rapidly, easily, and cost effectively using MSMS technology. It enables rationalisation of technology platforms in newborn screening by consolidating screening for haemoglobinopathies and inherited metabolic diseases onto MSMS.

Publisher

American Society of Hematology

Subject

Cell Biology,Hematology,Immunology,Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3