A Comparison of Normal Red Cell ATP Levels as Measured by the Firefly System and the Hexokinase System

Author:

BEUTLER ERNEST12,MATHAI CLARAMMA K.13

Affiliation:

1. Division of Medicine, City of Hope Medical Center, Duarte, California.

2. Division of Medicine, and Director, Department of hematology, City of Hope Medical Center, Duarte, Calif.; Clinical Professor of Medicine, California College of Medicine, Los Angeles, Calif.

3. Department of Hematology, City of Hope Medical Center, Duarte, Calif.

Abstract

Abstract Widely divergent normal red cell ATP levels have been reported by investigators using different methods. In order to clarify the cause of these discrepancies and to establish correct normal values for red cell ATP, the firefly technic for measuring ATP levels was compared with other methods. The ATP content of TCA filtrates of red cells was the same when determined by the firefly method as by the hexokinase-linked technic. Relatively low concentrations of protein were found to stimulate light output when lyophilyzed firefly extract, but not freshly prepared firefly extract, was used. Thus, falsely, high values were obtained when red cell extracts were examined, unless protein was also added to the standard. Storage of heparinized blood for as little as 1 hour resulted in a substantial decrease in red cell ATP levels. The loss with ACD blood was less, and could be obviated entirely by using an ACD solution with a pH adjusted to between 3.5 and 4.0. Removing the buffy coat or washing cells in saline resulted in no further loss of red cell ATP. Extraction of washed red cells with TCA resulted in an average loss of 4.6 per cent of ATP, while extraction of whole blood with TCA resulted in a 14 per cent loss of ATP. In contrast, perchloric acid extraction resulted in no ATP loss. If ATP determinations are carried out using the firefly method, protein should be added to the standard. If red cells must be stored for any period of time prior to extraction of ATP, an ACD solution with a pH of 3.5 to 4.0 should be used. If extracts of red cells are made, perchloric acid appears significantly superior to trichloroacetic acid.

Publisher

American Society of Hematology

Subject

Cell Biology,Hematology,Immunology,Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3