Conformation of von Willebrand factor in shear flow revealed with stroboscopic single-molecule imaging

Author:

Bergal Hans T.123ORCID,Jiang Yan234ORCID,Yang Darren235ORCID,Springer Timothy A.234ORCID,Wong Wesley P.2345ORCID

Affiliation:

1. 1Harvard Graduate Program in Biophysics, Harvard University, Boston, MA

2. 2Program in Cellular and Molecular Medicine, Boston Children’s Hospital, Boston, MA

3. 3Department of Biological Chemistry and Molecular Pharmacology, Blavatnik Institute at Harvard Medical School, Boston, MA

4. 4Department of Pediatrics, Harvard Medical School, Boston, MA

5. 5Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA

Abstract

Abstract von Willebrand factor (VWF) is a multimeric blood protein that acts as a mechanical probe, responding to changes in flow to initiate platelet plug formation. Previously, our laboratory tests had shown that using single-molecule imaging that shear stress can extend surface-tethered VWF, but paradoxically, we found that the required shear stress was higher than reported for free-in-flow VWF, an observation inconsistent with basic physical principles. To resolve this inconsistency critical to VWF’s molecular mechanism, we measured free-VWF extension in shear flow using pulsed laser stroboscopic imaging of single molecules. Here, laser pulses of different durations are used to capture multiple images of the same molecule within each frame, enabling accurate length measurements in the presence of motion blur. At high shear stresses, we observed a mean shift in VWF extension of <200 nm, much shorter than the multiple-micron extensions previously reported with no evidence for the predicted sharp globule-stretch conformational transition. Modeling VWF with a Brownian dynamics simulation, our results were consistent with VWF behaving as an uncollapsed polymer rather than the theorized compact ball. The muted response of free VWF to high shear rates implies that the tension experienced by free VWF in physiological shear flow is lower than indicated by previous reports and that tethering to platelets or the vessel wall is required to mechanically activate VWF adhesive function for primary hemostasis.

Publisher

American Society of Hematology

Subject

Cell Biology,Hematology,Immunology,Biochemistry

Reference63 articles.

1. von Willebrand factor, Jedi knight of the bloodstream;Springer;Blood,2014

2. Von Willebrand factor: form for function;Yee;Semin Thromb Hemost,2014

3. Biochemistry and genetics of von Willebrand factor;Sadler;Annu Rev Biochem,1998

4. New concepts in von Willebrand disease;Sadler;Annu Rev Med,2005

5. Function of von Willebrand factor in haemostasis and thrombosis;Reininger;Haemophilia,2008

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3