MiniMed 780GTM in children with type 1 diabetes under seven years of age: Prospective open-label, single-arm, double-center, follow-up study

Author:

Seget Sebastian1ORCID,Chobot Agata2ORCID,Rusak Ewa1ORCID,Ochab Agnieszka2,Bielawska Anna1,Polanska Joanna3ORCID,Jarosz-Chobot Przemysława1ORCID

Affiliation:

1. Department of Children’s Diabetology, Medical University of Silesia, Katowice, Poland

2. Department of Pediatrics, Institute of Medical Sciences, University of Opole, Opole, Poland

3. Department of Data Science and Engineering, Silesian University of Technology, Gliwice, Poland

Abstract

BACKGROUND: Given the steadily rising incidence of type 1 diabetes (T1D), particularly among the youngest preschool children, coupled with well-documented challenges of achieving and maintaining optimal metabolic control in this age group, there is a growing need for advanced technological devices. OBJECTIVE: To evaluate glycaemic control in children below the age of seven with type 1 diabetes (T1D) and assess the safety of the advanced hybrid closed loop (AHCL) system in comparison to the previous treatment method, a sensor-augmented pump with predictive low-glucose suspend (SAP-PLGS). METHOD: Data from 10 children (aged 2.60–6.98 years) with T1D who transitioned to the AHCL system from SAP-PLGS were analysed. SAP-PLGS records from two weeks prior to the initiation of AHCL were compared with records from the initial four weeks post-switch (excluding the training period). These data were examined at two 2-week intervals and compared with records from two weeks post six-month usage of the AHCL. RESULTS: A significant decrease in the average nighttime glucose concentration was observed compared to pre-AHCL values (p= 0.001, concordance W = 0.53). The Glucose Management Indicator (GMI) value significantly decreased from 6.88 ± 0.37% to 6.52 ± 0.32% (p= 0.018, rbc = 0.93) immediately following the device switch and stabilized at 6.50 ± 0.28% (p= 0.001, W = 0.53) and 6.55 ± 0.41% (p= 0.001, W = 0.53) at subsequent stages of the study. An improvement was also observed in mean glucose values for time spent < 54 mg/dl, while the proportion of time within this range was maintained, both during the day (p< 0.001, W = 0.58) and at night (p= 0.002, W = 0.83). CONCLUSION: The AHCL MiniMed 780GTM system improved glycaemic control in the studied group of children under seven years of age with T1D compared to previous SAP-PLGS therapy. It proved to be safe for delivering insulin in this age group.

Publisher

IOS Press

Subject

Health Informatics,Biomedical Engineering,Information Systems,Biomaterials,Bioengineering,Biophysics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3