Clinical boundary conditions for propagation-based X-ray phase contrast imaging: from bio-sample models targeting to clinical applications

Author:

Gobo M.S.S.1,Balbin D.R.1,Hönnicke M.G.2,Poletti M.E.1

Affiliation:

1. Departamento de Física, Faculdade de Filosofia Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, São Paulo, Brazil

2. Instituto Latino-Americano de Ciências da Vida e da Natureza, Universidade Federal da Integração Latino-Americana, Foz do Iguaçu, Brazil

Abstract

BACKGROUND: Typical propagation-based X-ray phase contrast imaging (PB-PCI) experiments using polyenergetic sources are tested in very ideal conditions: low-energy spectrum (mainly characteristic X-rays), small thickness and homogeneous materials considered weakly absorbing objects, large object-to-detector distance, long exposure times and non-clinical detector. OBJECTIVE: Explore PB-PCI features using boundary conditions imposed by a low power polychromatic X-ray source (X-ray spectrum without characteristic X-rays), thick and heterogenous materials and a small area imaging detector with high low-detection radiation threshold, elements commonly found in a clinical scenario. METHODS: A PB-PCI setup implemented using a microfocus X-ray source and a dental imaging detector was characterized in terms of different spectra and geometric parameters on the acquired images. Test phantoms containing fibers and homogeneous materials with close attenuation characteristics and animal bone and mixed soft tissues (bio-sample models) were analyzed. Contrast to Noise Ratio (CNR), system spatial resolution and Kerma values were obtained for all images. RESULTS: Phase contrast images showed CNR up to 15% higher than conventional contact images. Moreover, it is better seen when large magnifications (>3) and object-to-detector distances (>13 cm) were used. The influence of the spectrum was not appreciable due to the low efficiency of the detector (thin scintillator screen) at high energies. CONCLUSIONS: Despite the clinical boundary condition used in this work, regarding the X-ray spectrum, thick samples, and detection system, it was possible to acquire phase contrast images of biological samples.

Publisher

IOS Press

Reference67 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3