Affiliation:
1. Kyushu University, , Japan
Abstract
Accurate, easy, and fast inspection of defects on the backside of thick steel plates is essential for the maintenance of infrastructures. Low frequency eddy current testing (LF-ECT) is a promising method to detect defects of the backside of steel plates, with a thickness of approximately 10 mm. However, it is possible that the signal from the backside defect is smaller than that from the surface magnetic noise, causing difficulty identifying the backside defect. In this study, we propose a method to reduce the surface noise by employing a square wave inverter to generate a harmonic signal (rectangular wave ECT, or RECT), and the result demonstrates that the surface noise is successfully reduced using the harmonic signal.
Subject
Electrical and Electronic Engineering,Mechanical Engineering,Mechanics of Materials,Condensed Matter Physics,Electronic, Optical and Magnetic Materials
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献