Affiliation:
1. RIKEN Center for Advanced Photonics, RIKEN, Japan
2. Oriental Shiraishi Corporation, Japan
Abstract
We have started the development of a transportable neutron salt-meter, we call it RANS-μ, combining a 252Cf neutron source and a prompt gamma neutron activation analysis. Trials of chloride detection measurement with RANS-μ were performed outdoor using removed bridges damaged by chloride attack at an outdoor yard in Public Works Research Institute (PWRI) and a test bridge in Fukushima Robot Test Field. For the measurement at PWRI, the results obtained by RANS-μ were compared with those of the automatic potentiometric titration by drilled powder, and then consistent results were obtained.
Subject
Nuclear Energy and Engineering,Nuclear and High Energy Physics
Reference12 articles.
1. Nondestructive measurement method to detect water/void inside slabs using compact neutron source by backscattered neutrons;Ikeda;Journal of Advanced Concrete Technology,2017
2. JIS A 1154, Methods of test for chloride ion content in hardened concrete, (in Japanese).
3. JSCE, Standard Specifications for Concrete Structures-2012 “Design”, 2012 (in Japanese).
4. Area analysis method of elements distribution in concrete by using EPMA;JSCE-G 574;Concrete Journal,2006
5. On-site elemental analysis of concrete by portal energy dispersive X-ray fluorescence analyzer;Kanada;Concrete Journal,2006
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献