Determination of virtual source position using back projecting zero and convergent arcTAN method for scanning-passive scatter beam in carbon ion therapy

Author:

Meng Wan-Bin1,Li Qiang2,Ye Yan-Cheng3,Wu Jia-Ming345

Affiliation:

1. University of Chinese Academy of Sciences, Beijing, China

2. Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China

3. Heavy Ion Center of Wuwei Cancer Hospital; Gansu Wuwei Academy of Medical Sciences, Gansu Wuwei Tumor Hospital, Wuwei City, Gansu Province, China

4. Department of Medical Physics, Chengde Medical University, Chengde City, Hebei Province, China

5. Department of Radiation Oncology, Yee Zen General Hospital, Tao Yuan City, Taiwan

Abstract

OBJECTIVE: This study aims to develop and test a new technique by using the convergent arcTAN (cATAN) method capable of dealing with the virtual source position delivered by different carbon ion energies from the pattern of scanning-passive scatter beam. MATERIALS AND METHODS: A homemade large-format CMOS sensor and Gaf Chromic EBT3 films are used for the virtual source position measurement. The Gaf films are embedded in a self-designed rectangular plastic frame to tighten films and set up on a treatment couch for irradiation in air with the film perpendicular to the carbon ion beam at the nominal source-axis-distance (SAD) as well as upstream and downstream from the SAD. The horizontal carbon ion beam with 5 energies at a machine opening field size is carried out in this study. The virtual source position is determined by using the convergent arcTAN (cATAN) method and compared with a linear regression by back projecting FWHM to zero at a distance upstream from the various source-film-distance. RESULTS: The film FWHM measurement error of 0.5 mm leads to 0.001% deviation of α (cATAN) at every assumed textend. The overall uncertainty for the reproducibility of calculated virtual source position by the assumed textend in the vertical and horizontal directions amounts to 0.1%. The errors of calculated virtual source position by assumed textend with back projecting FWHM to zero methods are within 1.1±0.001, p = 0.033. CONCLUSION: We develop a new technique capable of dealing with the virtual source position with a convergent arcTAN method to avoid any manual measurement mistakes in scanning-passive scatter carbon ion beam. The readers are encouraged to conduct the proposed cATAN method in this study to investigate the virtual source position in the Linac-based external electron beams and the proton beams.

Publisher

IOS Press

Subject

Electrical and Electronic Engineering,Condensed Matter Physics,Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

Reference18 articles.

1. Determination of the virtual electron source of a betatron;Shroder-Babo;Acta Radiol,1983

2. Determination of the source position for the electron beam rom a high-energy linear accelerator;Jamshidi;Med Phys,1986

3. Effect of air space on depth dose in electron beam therapy;Khan;Radiology,1978

4. Multiple Coulomb scattering of 160MeV protons;Gottschalk;Nucl Instrum Methods Phys Res B,1993

5. An analytical approximation of depth– dose distributions for theraputic proton beams;Bortfeld;Phys Med Biol,1996