Optimal allocation of hybrid energy storage capacity of DC microgrid based on model predictive control algorithm

Author:

Zhao Jie1,Wang Shuo1,Wu Haotian2

Affiliation:

1. State Grid Hebei Electric Power Company Shijiazhuang Power Supply Company, Shijiazhuang, Hebei, China

2. Shanghai Investigation, Design & Research Institute Co., Ltd, Shanghai, China

Abstract

To effectively enhance the safety, stability, and economic operation capability of DC microgrids, an optimized control strategy for DC microgrid hybrid energy storage system (HESS)(The abbreviation table is shown in Table 2) based on model predictive control theory is proposed. Based on the characteristics of supercapacitors and batteries, system safety requirements, and various constraints, a predictive model for a hybrid energy storage DC microgrid is established. By defining its optimization indicators, designing an energy optimization management strategy, and transforming it into a quadratic programming problem for solution, the reasonable scheduling of power in the DC microgrid has been achieved. In addition, a power control method was proposed for the system without constraints. The simulation experiment results show that at the initial sampling time, the system operates normally, and the MPC algorithm allocates two types of energy storage devices to discharge to meet the net load demand, without absorbing electricity from the external network. At the 30th sampling point, the net load increases, and the MPC controller obtains the optimal solution of the control problem based on the known net load prediction data at the previous sampling time. It outputs the operating reference values of each output unit at the next time. Starting from the 100th to 199th sampling points, SOCUC falls below the lower limit of the safety interval, and the system enters situation 4 mode. The external network output assists the battery in working. At the 131st sampling point, the net load decreases, the system enters Situation 3 mode, and the battery operates independently. Until the 179th point, SOCB was also below the lower limit of its safety interval, and the system entered situation 5 mode, completely maintaining system power balance by external network power. Starting from point 201, the net load becomes negative, and the system charges the HESS according to instructions and stops the external power grid energy transmission. Conclusion: The feasibility and effectiveness of the proposed optimization management strategy have been verified.

Publisher

IOS Press

Subject

Artificial Intelligence,General Engineering,Statistics and Probability

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司