Visual function assessment of Chinese cataract patients after individual aspheric intraocular lens implantation according to preoperative cornea spherical aberration

Author:

Duan Lian11,Dang Guangfu11,Ge Jinling21,Gao Yang1,Wang Lihua3

Affiliation:

1. Department of Ophthalmology, Qianfoshan Hospital Affiliated to Shandong University, Jinan, Shandong, China

2. Mingshui Eye Hospital, Jinan, Shandong, China

3. Department of Ophthalmology, Shandong Provincial Hospital Affiliated to Shandong University, Jinan, Shandong, China

Abstract

BACKGROUND: Aspheric intraocular lens (IOLs) implantation has been widely applied in cataract surgery. However, there is no consensus on the optimal guidance for the operations in IOLs implantation. OBJECTIVE: This study evaluated the visual function of Chinese cataract patients six months after cataract surgery with two different guiding ideologies. METHODS: We evaluated 50 patients (61 eyes) with implantation of different aspheric IOLs (SN60WF IOLs, ZCB00 IOLs, PY-60AD IOLs, AO IOLs) 6 months after cataract surgery. Twenty-four patients (30 eyes) under individual implantation were ascribed to group 1 and 26 patients (31 eyes) with randomized implantation were ascribed to the control group (group 2). Postoperatively parameters included monocular best-corrected visual acuity (BCVA), contrast sensitivity (CS), total spherical aberration Z (4, 0) at 5 mm pupil size, and patient satisfaction. The quality of life after operation was assessed through the National Eye Institute Visual Function Questionnaire-25 (NEI VFQ-25). RESULTS: Six months after cataract operation, the contrast sensitivity with glare of group 1 at 2.5∘ was 0.697 ± 0.027, and 0.532 ± 0.049 in group 2. Besides, there was no significant difference at any other special frequency. The mean spherical aberration Z (4, 0) at 5 mm pupil size in group 1 was 0.015 ± 0.028 um, and in group 2 was 0.043 ± 0.109 um, with a significant difference (p< 0.01). The mean scores obtained from NEI VFQ-25 were not significantly different. CONCLUSION: It is effective to implant aspheric IOLs individually according to preoperative corneal spherical aberration. Patients obtained better contrast sensitivity with glare at 2.5∘, but there was no significant difference in BCVA, contrast sensitivity at other special frequency, and subjective visual function.

Publisher

IOS Press

Subject

Health Informatics,Biomedical Engineering,Information Systems,Biomaterials,Bioengineering,Biophysics

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3