Bedside sonography performed by neonatology residents to confirm central vascular catheter position in neonates – A Prospective Diagnostic Evaluation study

Author:

Shabeer M.P.1,Abiramalatha T.12,Gibikote S.3,Rebekah G.4,Thomas N.1

Affiliation:

1. Department of Neonatology, Christian Medical College, Vellore, Tamil Nadu, India

2. Department of Neonatology, Sri Ramachandra Institute of Higher Education and Research (SRIHER), Chennai, India

3. Department of Radiology, Christian Medical College, Vellore, Tamil Nadu, India

4. Department of Biostatistics, Christian Medical College, Vellore, Tamil Nadu, India

Abstract

OBJECTIVE: To evaluate the diagnostic accuracy and utility of bedside ultrasound (US) by neonatology residents to confirm position of umbilical venous catheter (UVC), umbilical arterial catheter (UAC), and peripherally inserted central catheter (PICC). METHODS: In this prospective study, we included neonates who required UVC, UAC or PICC insertion. Two neonatology residents performed all bedside US examinations after a short period of training. Plain radiograph was taken as gold standard. Time taken for confirmation of catheter position by US and radiograph was recorded. RESULTS: We recruited 71 neonates for UVC and UAC, and 40 neonates for PICC. Sensitivity and specificity of US in identifying a malpositioned catheter was good for UVC (94% and 66.7% respectively) and UAC (86.7% and 94.5%). Agreement between radiograph and US was good for UVC [0.718 (0.512, 0.861); p < 0.001] and UAC [0.857 (0.682, 0.953); p < 0.001]. Sensitivity (47.8%) of US in identifying a malpositioned PICC was low, though specificity (82.4%) was good. Agreement between radiograph and US in identifying PICC position was poor [0.25 (–0.084, 0.545); p 0.024]. This was due to incorrect interpretation of catheter position on radiograph in some infants, which was confirmed by the radiologist. The median time taken for US was significantly less than time taken for radiograph in confirming the position of UVC (50 vs. 155 minutes; p < 0.001)), UAC (45 vs. 128 minutes; p < 0.001), and PICC (60 vs. 136 minutes; p < 0.001). CONCLUSION: US examination byneonatology residents has good diagnostic accuracy in confirming the position of UAC and UVC, and possibly PICC in neonates. The time taken to confirm catheter position by US is significantly less than radiograph.

Publisher

IOS Press

Subject

Pediatrics, Perinatology, and Child Health

Reference24 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3