Definition of catheter jamming: A mechanical analysis of catheter fracture tension and fracture strain

Author:

Li Feng-Xian1,Su Peng2,Li Yan-Ping1,Tian Mei-Jing1,Zhang Hong-Yang1,Gao Huan-Huan1

Affiliation:

1. Department of Oncology, Beijing Shijingshan Hospital, Capital Medical University, Beijing, China

2. Department of Orthopedics, Beijing Shijingshan Hospital, Capital Medical University, Beijing, China

Abstract

BACKGROUND: Catheter jamming is an emerging and possibly underrated complication. OBJECTIVE: To find the criteria for determining if the catheter cannot be removed through the mechanical analysis of fracture tension and fracture strain (εf) of Peripheral Inserted Central Catheters (PICC). METHOD: We removed 30 pieces of PICC catheters from patients and recorded the indwelling time. Those with an indwelling time shorter than 12 weeks belonged to the short-term group. Those with an indwelling time longer than 12 weeks belonged to the long-term group. The first half of the same catheter is section A, and the second half is section B. The fraction tension and fracture strain of the catheter were measured, and statistical analysis was conducted. RESULTS: The fracture tension of catheter in sections A and B were 5.8917 ± 1.0095 and 6.0670 ± 0.8066 Newtons respectively (p= 0.393) and the fracture strain of catheter in sections A and B were 6.0611 ± 1.0810 and 6.2543 ± 0.7187 Newtons respectively (p= 0.343). The fracture tension of catheter in short-term and long-term group were 6.0696 ± 0.9414 and 5.9192 ± 0.8972 Newtons respectively (p= 0.535) and the fracture strain of catheter in short-term and long-term group were 6.0067 ± 0.7227 and 6.2584 ± 1.0212 respectively (p= 0.301). CONCLUSION: It is objective and consistent to take the catheter fracture tension as the standard. This standard would be able to accurately define the concept of catheter failure and reduce the risk of catheter fracture and the misdiagnosis of catheter failure. The catheter fracture tension and fracture strain was not affected by the catheter indwelling time. It is recommended to set the tensile force as 5 Newtons and carry it out at a speed of 100 mm/min for the catheter drawing of the PICC single-lumen silicone catheter (4.0F) from Budd Company.

Publisher

IOS Press

Subject

Health Informatics,Biomedical Engineering,Information Systems,Biomaterials,Bioengineering,Biophysics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3