CT diagnostics of pulmonary embolism: Does iodine delivery rate still affect image quality in iterative reconstruction?

Author:

Burdenski Thomas1,Bressem Keno K.12,Adams Lisa C.12,Grauhan Nils F.1,Niehues Stefan M.1

Affiliation:

1. Institute for Radiology, Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt Universität zu Berlin, Berlin, Germany

2. Berlin Institute of Health at Charité – Universitätsmedizin Berlin, Berlin, Germany

Abstract

BACKGROUND: Computed tomographic (CT) imaging in suspected pulmonary artery embolism represents the standard procedure. Studies without iterative reconstruction proved beneficial using increased iodine delivery rate (IDR). This study compares image quality in pulmonary arteries on iteratively reconstructed CT images of patients with suspected pulmonary embolism using different IDR. MATERIAL AND METHODS: 1065 patients were included in the study. Patients in group A (n = 493) received an iodine concentration of 40 g/100 ml (IDR 1.6 g/s) and patients in group B (n = 572) an iodine concentration of 35 g/100 ml (IDR 1.4 g/s) at a flow rate of 4 ml/s. A 80-detector spiral CT scanner with iterative reconstruction was used. We measured mean density values in truncus pulmonalis, both pulmonary arteries and segmental pulmonary arteries. Subjectively, the contrast of apical and basal pulmonary arteries was determined on a 4-point Likert scale. RESULTS: Radiodensity was significantly higher in all measured pulmonary arteries using the increased IDR (p < 0.001). TP: 483.0 HU vs. 393.4 HU; APD: 452.1 HU vs. 372.1 HU; APS: 448.2 HU vs. 374.4 HU; ASP: 443.9 vs. 374.4 HU. Subjectively assessed contrast enhancement in apical (p = 0.077) and basal (p = 0.429) lung sections showed no significant differences. CONCLUSION: Higher IDR improves objective image quality in all patients with significantly higher radiodensities by iterative reconstruction. Subjective contrast of apical and basal lung sections did not differ. The number of non-sufficient scans decreased with high IDR.

Publisher

IOS Press

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine,Hematology,Physiology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3