The Association Between Physical Activity/Heart Rate Variability Data Obtained Using a Wearable Device and Timed Motor Functional Tests in Patients with Duchenne Muscular Dystrophy: A Pilot Study

Author:

Nakamura Akinori1,Matsumura Tsuyoshi2,Takeshima Yasuhiro3,Kuru Satoshi4,Imazaki Manami5,Nonomura Hidenori5,Kaiya Hisanobu6

Affiliation:

1. Department of Clinical Research, NHO Matsumoto Medical Center, Matsumoto, Japan

2. Department of Neurology, NHO Osaka Toneyama Medical Center, Toneyama, Osaka, Japan

3. Department of Pediatrics, Hyogo Medical University, Nishinomiya, Hyogo, Japan

4. Department of Neurology, NHO Suzuka National Hospital, Suzuka, Japan

5. Takeda Development Center Japan, Takeda Pharmaceutical Company Limited, Osaka, Japan

6. Clinical Trials Accelerating Organization, Japan Muscular Dystrophy Association, Tokyo, Japan

Abstract

Background: Duchenne muscular dystrophy (DMD) is a devastating X-linked muscle disease. Clinical evaluation of DMD uses patient-intensive motor function tests, and the recent development of wearable devices allows the collection of a variety of biometric information, including physical activity. Objective: In this study, we examined differences in physical activity and heart rate variability (HRV) between patients with DMD and healthy subjects using a wearable device, and investigated any association between these parameters and motor function in patients with DMD. Methods: Participants were 7 patients with DMD and 8 healthy males, whose physical activity and HRV were provided by a wearable device. These data were used to investigate the relationship between both physical activity and HRV parameters and timed motor functional tests [Time to stand from supine, 10-meter walking time (10MWT), North Star Ambulatory Assessment (NSAA), and 6-minute walking test (6MWT)] in patients with DMD. Results: Results of 24-hours physical activity, fat burning, total number of steps and active distance, average step rate, average exercise intensity during walking, exercise, degree of forward lean during walking, maximum heart rate, normalized low frequency power (LF norm), and maximum exercise intensity in patients with DMD were lower than those in control subjects. Physical activity and HRV parameters did not correlate with the time to stand from supine. The 10MWT positively correlated with average heart rate, while NSAA negatively correlated with average heart rate, total frequency power (TF), and very low frequency power (VLF) during arousal. The 6MWT negatively correlated with ratio LF/high frequency power (HF). CONCLUSIONS: Physical activity and HRV indices that differ from those of normal children and that correlate with motor function assessment may serve as digital biomarkers.

Publisher

IOS Press

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3