Comparison of thrombosis risk in an abdominal aortic dissection aneurysm with a double false lumen using computational fluid dynamic simulation method

Author:

Chen Hongbing1,Su Tong2,Wang Qi1,Zheng Zhe1,Li Hongwei3,Li Jianbo1

Affiliation:

1. Department of Forensic Medicine, College of Basic Medicine, Chongqing Medical University, Chongqing, China

2. Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China

3. Institute of Forensic Science, Chongqing Public Security Bureau, Chongqing, China

Abstract

BACKGROUND: Aneurysms are associated with a mortality rate of 81% or more in cases of rupture. OBJECTIVE: To analyse the haemodynamic indices and compare the thrombosis risk in a double false lumen abdominal aortic dissection aneurysm using computational fluid dynamics (CFD). METHODS: Computer tomography angiography (CTA) imaging data were collected from a patient with a double false lumen abdominal aortic dissection aneurysm, and three different lesion morphology aneurysm models were established, double false lumen abdominal aortic dissection aneurysm, single false lumen abdominal aortic dissection aneurysm and saccular abdominal aortic aneurysm, in order to analyse the flow velocity, time-averaged shear stress (TAWSS), oscillatory shear index (OSI), relative residence time (RRT) of blood flow, and endothelial cell activation potential (ECAP). RESULTS: All three aneurysms were in a low-flow state within the body, and the low-flow velocity flow in the proximal vessel wall extended to the right common iliac artery; the vortex intensity was more intense in the abdominal aortic dissection aneurysm than in the saccular abdominal aortic aneurysm. The risk area for thrombosis was concentrated in the expansion part of the aneurysm and the false lumen. The RRT and ECAP maxima of the double false lumen abdominal aortic dissection aneurysm were much greater than those of the single false lumen dissection aneurysm and saccular aortic aneurysm. CONCLUSION: Low-velocity blood flow, high OSI, low TAWSS, high RRT, and high ECAP regions correlate with the risk of thrombosis. The double false lumen type of abdominal aortic dissection aneurysm had some specificity in this case. The risk of thrombosis in the patient was extremely high, and the largest risk zone was within the smaller false lumen, which could be because the smaller false lumen was connected to the true lumen by only one breach. The results of the study provide some guidance in the early screening and development of treatment plans.

Publisher

IOS Press

Subject

Health Informatics,Biomedical Engineering,Information Systems,Biomaterials,Bioengineering,Biophysics

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3