Improvement of imaging and image correction methods for the soft X-ray projection microscopy

Author:

Jigmeddorj Vanchinkhuu1,Jamsranjav Erdenetogtokh2,Baatar Duurenbuyan12,Kinjo Yasuhito3,Ito Atsushi4,Shiina Tatsuo5

Affiliation:

1. Department of Physics, School of Arts and Sciences, National University of Mongolia, Ulaanbaatar, Mongolia

2. Laboratory of Radiation Biophysics, Institute of Physics and Technology, Mongolian Academy of Sciences, Ulaanbaatar, Mongolia

3. Institute of Materials Structure Science, High Energy Accelerator Research Organization, Ibaraki, Japan

4. School of Engineering, Tokai University, Kanagawa, Japan

5. Graduate school of Engineering, Chiba University, Chiba, Japan

Abstract

BACKGROUND: The soft X-ray projection microscope has been developed for high resolution imaging of hydrated bio-specimens. Image blurring due to X-ray diffraction can be corrected by an iteration procedure. The correction is not efficient enough for all images, especially for low contrast chromosome images. OBJECTIVE: The purpose of this study is to improve X-ray imaging techniques using a finer pinhole and reducing capture time, as well as to improve image correction methods. A method of specimen staining prior to the imaging was tested in order to capture images with high contrasts. The efficiency of the iteration procedure and its combined version with an image enhancement method was also assessed. METHODS: In image correction, we used the iteration procedure and its combined version with an image enhancement technique. To capture higher contrast images, we stained chromosome specimens with the Platinum blue (Pt-blue) prior to the imaging. RESULTS: The iteration procedure combined with image enhancement corrected the chromosome images with 329 or lower magnification effectively. Using the Pt-blue staining for the chromosome, images with high contrast have been captured and successfully corrected. CONCLUSIONS: The image enhancement technique combining contrast enhancement and noise removal together was effective to obtain higher contrast images. As a result, the chromosome images with 329 or lower times magnification were corrected effectively. With Pt-blue staining, chromosome images with contrasts of 2.5 times higher than unstained case could be captured and corrected by the iteration procedure.

Publisher

IOS Press

Subject

Electrical and Electronic Engineering,Condensed Matter Physics,Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3