Abstract

BACKGROUND: Pulse oximetry measures heart rate (HR) and percent oxygen saturation (SpO2). For aerobic exercise, whereby cellular oxygen demand and delivery are elevated and maintained for extended periods, HR and SpO2 values are consistent when measured by pulse oximetry. Yet due to its intermittent nature, HR and SpO2 values from resistive exercise may exhibit lower data reliability and repeatability. OBJECTIVE: Assess intra-rater reliability and repeatability of pulse oximetry HR and SpO2 values from two identical resistive exercise protocols. METHODS: Subjects (n= 32) performed two calf press workouts on a flywheel-based ergometer as HR and SpO2 were measured before, between sets, and after exercise. Workouts entailed a 4-set 15-repetition protocol separated by 120-second rests. Intra-rater reliability was assessed with intraclass correlation coefficients (ICC). Repeatability was measured by the smallest real difference in absolute and relative terms. RESULTS: ICC and standard error of estimate results for HR ranged from 0.60–0.79 and 9.1–13.0 respectively. SpO2 ICC and standard error of estimate results ranged from 0.16–0.71 and 1.44–4.33 respectively. Between sets, smallest real difference values tended to be less for HR. CONCLUSIONS: Results demonstrate acceptable intra-rater reliability and repeatability for HR, but not SpO2 which we attribute to the exercise mode and protocol examined.

Publisher

IOS Press

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine,Biophysics

Reference28 articles.

1. Validity of pulse oximetry during maximal exercise in normoxia, hypoxia, and hyperoxia;Yamaya;J Appl Physiol.,2002

2. The use of pulse oximetry at high altitude;Tannheimer;Res Invest Sports Med.,2020

3. Usability of pulse oximetry during severe physical exercise at high altitude;Tannheimer;Ger J Sports Med.,2018

4. Validity of pulse oximetry during exercise in elite endurance athletes;Martin;J Appl Physiol.,1992

5. A review of the principles and accuracy of pulse oximeter estimates during exercise;Mengelkoch;Phys Ther.,1994

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献