The clinical effect of the digital guide in the early implant restoration of second molars

Author:

Wang Zou1,Hu Chen1,Zhang Yanli2,Wang Linlin3,Shao Longquan12,You Jie1

Affiliation:

1. Department of Stomatology, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong, China

2. Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou, Guangdong, China

3. Department of Stomatology, Hainan General Hospital ⋅ Hainan Affiliated Hospital of Hainan Medical University, Haikou, Hainan, China

Abstract

BACKGROUND: In the absence of contraindications to implants, implant repair is the preferred method to treat mandibular second molar loss. OBJECTIVE: To compare the clinical effects of a traditional implant guide and digital implant guide in the early implant restoration of second molars. METHODS: The study included 35 patients with second molar loss randomly divided into two groups. Eighteen patients in the experimental group had an implant procedure using a computer-aided design/computer-assisted manufacturing (CAD/CAM) digital implant guide, and 17 patients in the control group had the procedure using a traditional film pressing implantation guide. Then, the surgical procedure was completed using the two different implant guides. At 3 months after surgery, four parameters including screw hole exit position, coronal deviation of the implant site, disease improvement rate, and clinical effects, which included marginal adaptation, anatomic form, marginal discoloration, postoperative sensitivity, surface roughness, and secondary caries of the upper prosthesis were compared between the two groups. RESULTS: The screw hole exit position in the experimental group was directed to the functional cusp of the opposite jaw, and there was a statistically significant difference between the two groups. There was no statistically significant difference in the rate of disease improvement and the clinical effect of the upper prosthesis between the two groups. There was no statistically significant difference in the bilateral coronal deviation and deviation direction of implants in the two groups. The bilateral coronal deviation of the experimental group was smaller than that of the control group. CONCLUSION: The digital implant guide can effectively reduce the deviation of the screw hole and the upper prosthesis in the restoration of the second molar. The prosthesis used in the experimental group had a good clinical outcome, which provides a theoretical basis for the restoration of the posterior molar.

Publisher

IOS Press

Subject

Health Informatics,Biomedical Engineering,Information Systems,Biomaterials,Bioengineering,Biophysics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3