Novel CAD-CAM zirconia coping design to enhance the aesthetics and strength for anterior PLZ crowns

Author:

Alsubaiy Ebrahim Fihaid1,Chaturvedi Saurabh1,Qutub Osama A.2,Mously Hisham Abdullah2,Zarbah Mohammad Abdullah1,Haralur Satheesh B.1,Bhagat Tushar V.3

Affiliation:

1. Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia

2. Oral and Maxillofacial Prosthodontics Department, College of Dentistry, King Abdulaziz University, Saudi Arabia

3. College of Dentistry, Prince Sattam bin Abdulaziz University, AlKharj, Saudi Arabia

Abstract

BACKGROUND: The aesthetics and strength of anterior porcelain layered zirconia (PLZ) crowns are mainly affected by the zirconia (Zr) coping design. There is a need for a modified design to enhance aesthetics with strength. OBJECTIVES: The purpose of this study was to compare the fracture resistance of anterior PLZ crowns having modified CAD-CAM Zr coping designs (in terms of thickness and marginal collar designs) with standard Zr copings. METHODS: Fifty PLZ crowns were fabricated and divided into two groups: Gr 1: Standard Zr Coping (SZC) (control gr) with 0.5 mm thickness (Facial-F, Mesial-M, Distal-D, incisal-I, and Palatal-P) without a collar; Gr 2: Collar Zr Coping (CZC) (test gr) with 2.5 mm collar height on M, D, P and 0.2 mm F and variable facial wall thickness. Subgroups: Gr 2a: (CZC-0.5 mm) facial wall thickness 0.5 mm; Gr 2b: (CZC-0.4 mm) facial wall thickness 0.4 mm; Gr 2c: (CZC-0.3 mm) facial wall thickness 0.3 mm; Gr 2d: (CZC-0.2 mm) facial wall thickness 0.2 mm. The fracture load was determined and analysed using One-way ANOVA and Dunnet test. RESULTS: The minimum fracture load was 927.36 ± 127.80 N observed for Gr 2c (CZC at 0.3 mm) while the maximum fracture load was 1373.61 ± 146.54 N observed for Gr 2a (CZC at 0.5 mm). A highly significant difference in mean fracture load among various Zr coping groups (p< 0.001) was determined. CONCLUSIONS: Novel Zr coping design for anterior PLZ crowns can provide better aesthetics with strength. Reducing the thickness of Zr coping in the aesthetic zone to 0.2 mm and providing a modified collar design (2.5 mm collar height on M, D, P, and 0.2 mm F) would provide strength without jeopardizing aesthetics.

Publisher

IOS Press

Subject

Health Informatics,Biomedical Engineering,Information Systems,Biomaterials,Bioengineering,Biophysics

Reference50 articles.

1. Recent developments in restorative dental ceramics;Anusavice;J Am Dent Assoc,1993

2. State of the art of zirconia for dental applications;Denry;Dent Mater,2008

3. Ceramics in dentistry: historical roots and current perspectives;Kelly;J Prosthet Dent,1996

4. Survival of zirconia- and metal-supported fixed dental prostheses: a systematic review;Heintze;Int J Prosthodont,2010

5. Complete and partial contour zirconia designs for crowns and fixed dental prostheses: a clinical report;Marchack;J Prosthet Dent,2011