Redesign and ergonomic assessment of a chest-support baby walker

Author:

Golmohammadpour Hamedeh1,Garosi Ehsan2,Taheri Mostafa3,Dehghan Naser4,Ezbarami Sahebeh Mirzaei5,Karanikas Nektarios6

Affiliation:

1. Department of Industrial and System Engineering, The State University of New York at Buffalo, Getzville, NY, USA

2. Department of Ergonomics, School of Public Health, Iran University of Medical Sciences, Tehran, Iran

3. Department of Architecture, Faculty of Arts and Architecture, Science and Research Branch, Islamic Azad University, Tehran, Iran

4. Ambient Intelligence Laboratory (AMI-Lab), Computer Science Department, Faculty of Science, University of Sherbrooke, Sherbrooke, QC, Canada

5. Department of Biomechanics, Science and Research Branch, Islamic Azad University, Tehran, Iran

6. School of Public Health and Social Work, Queensland University of Technology, Brisbane, QLD, Australia

Abstract

BACKGROUND: Parents often use baby walkers (BWs) as assistive devices to improve their infants’ independent movement and motor skill acquisition. However, the literature suggests that conventional baby walkers (CBW) may cause delays in an infant’s ability to walk independently and musculoskeletal burden on parents. OBJECTIVE: In the current study, a baby walker (RBW) with chest support was redesigned and ergonomically assessed during an infant-walking task. METHODS: The anthropometric dimensions of 90 infants aged 7–11 months were measured in the city of Urmia, northwestern Iran. Following redesigning based on the results from expert panel meetings and prototyping of the RBW, 18 mothers (age: 28.33±4.27 and height: 163.75±5.32 and weight: 59.45±5.99) with their infants (9 boys and 9 girls) performed a simulated infant walking task in two experimental sessions using the CBW and RBW over a repeated measurements design. The infants’ feet track patterns, including the number of steps and step distances were assessed via the image analysis of the footprints. The mothers’ body posture and lower back spinal load were evaluated using Rapid Upper Limb Assessment (RULA) technique and 3D Static Strength Prediction Program (3DSSPP), respectively. RESULTS: Wilcoxon signed-rank tests showed infants walked more steps with the RBW (p = 0.002). Similarly, the distance between the infants’ left heel strike (p = 0.008) and their right and left toe-off (p = 0.03 and 0.02 respectively) was also significantly lower in the RBW use. Additionally, the body posture of mothers was improved (RULA final score from 7 for CBW to 5 for RBW). Moreover, lower back compression and shear forces were reduced significantly (p = 0.002) by the RBW use. CONCLUSION: According to the feet track pattern, infants took more balanced steps when the RBW was used. In addition, mothers were subjected to less pressure on the lumbar region when they placed and lifted their infant from the RBW. However, further work is necessary to investigate potential long-term effects of the RBWs use.

Publisher

IOS Press

Subject

Public Health, Environmental and Occupational Health,Rehabilitation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3