Evaluation of a shorter algorithm in an automated analysis of sublingual microcirculation

Author:

Bruno Raphael Romano1,Schemmelmann Mara1,Wollborn Jakob23,Kelm Malte14,Jung Christian1

Affiliation:

1. Department of Cardiology, Pulmonary Diseases, and Vascular Medicine, Medical Faculty, University Hospital Düsseldorf, Düsseldorf, Germany

2. Department of Anesthesiology and Critical Care, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany

3. Department of Anesthesiology, Perioperative and Pain Medicine, Brigham and Women’s Hospital, Boston, MA, USA; Harvard Medical School, Boston, MA, USA

4. Cardiovascular Research Institute Düsseldorf (CARID), Düsseldorf, Germany

Abstract

OBJECTIVE: Diagnostic and risk stratification in intensive and emergency medicine must be fast, accurate, and reliable. The assessment of sublingual microcirculation is a promising tool for this purpose. However, its value is limited because the measurement is time-consuming in unstable patients. This proof-of-concept validation study examines the non-inferiority of a reduced frame rate in image acquisition regarding quality, measurement results, and time. METHODS: This prospective observational study included healthy volunteers. Sublingual measurement of microcirculation was performed using a sidestream dark field camera (SDF, MicroVision Medical®). Video-quality was evaluated with a modified MIQS (microcirculation image quality score). AVA 4.3C software calculated microcirculatory parameters. RESULTS: Thirty-one volunteers were included. There was no impact of the frame rate on the time needed by the software algorithm to measure one video (4.5 ± 0.5 minutes) for AVA 4.3C. 86 frames per video provided non inferior video quality (MIQS 1.8 ± 0.7 for 86 frames versus MIQS 2.2 ± 0.6 for 215 frames, p < 0.05), equal results for all microcirculatory parameters, but did not result in an advantage in terms of speed. No complications occurred. CONCLUSION: Video captures with 86 frames offer equal video quality and results for consensus parameters compared to 215 frames. However, there was no advantage regarding the time needed for the overall measurement procedure.

Publisher

IOS Press

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine,Hematology,Physiology

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3