Dynamic endoluminal contrast enhanced ultrasound (CEUS) for display of drainages in inflammatory abdominal fluid collections1

Author:

Jung E.M.1,Jung F.2,Stroszczynski C.1,Wiesinger I.1

Affiliation:

1. Department of Radiology, University Medical Center Regensburg, Germany

2. Institute of Biotechnology, Molecular Cell Biology, Brandenburg University of Technology, Senftenberg, Germany

Abstract

AIM: To evaluate the additive clinical value of endoluminal contrast enhanced ultrasound (CEUS) after interventional placement of drainages in abdominal fluid collections. MATERIAL/METHOD: Examination of 30 patients using a 1–6 MHz convex probe (Resona 7, Mindray) to locate the fluid collection in B-Mode. Additionally, dynamic endoluminal CEUS with 1 ml sulphur-hexafluoride microbubbles was performed to measure the extent of the percutaneously drained abscesses. Independent assessment of dynamically stored images in PACS in DICOM format. Correlation to reference imaging using computed tomography (CT). RESULTS: A total of 30 patients were examined (17 m, 19–78 years, mean 56.1 years). Drainages were positioned in the liver in 15 cases, in the pelvis after kidney transplantation in 4 cases, close to the spleen in 1 case, and in the abdomen in 10 cases. In all cases abscesses showed marginal hyperaemia with reactive septations in CEUS. The drainage position was assessed by means of B-mode in all cases first and then by CEUS. In 4 cases CEUS showed a fistula to the pleura, in 5 cases to the peritoneum, in 2 cases to the intestine, in 5 cases to the biliary tract, corresponding to the CT. In 2 cases there was a hint of an anastomotic leakage after intestinal anastomosis, which was reliably detected by CT. The drainage was removed in 11 cases within a period of 2 to 5 days after CEUS control, in 9 cases within a period of 5 to 10 days. Another operation was necessary in 3 cases. A new drainage was placed in 2 cases. The required amount of ultrasound contrast medium is 1 ml endoluminally diluted to 9 ml sodium chloride. CONCLUSION: CEUS facilitates the exact localization and characterization of inflammatory abdominal fluid collections. Furthermore, possible fistulas can be detected that cannot be seen with conventional ultrasound.

Publisher

IOS Press

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine,Hematology,Physiology

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3