Liver stiffness measured with two-dimensional shear wave elastography comparable to histopathology falls dominantly on the severe liver fibrosis

Author:

Li Ya1,Wu Size1ORCID

Affiliation:

1. Department of Ultrasound, The First Affiliated Hospital of Hainan Medical University, Haikou, China

Abstract

BACKGROUND: Two-dimensional shear-wave elastography (2D-SWE) has been used for years for liver assessment of patients with chronic hepatitis B (CHB), but its effectiveness remains unclear in different populations and using different ultrasound systems. OBJECTIVE: This study investigated the effectiveness of 2D-SWE in evaluating liver fibrosis in patients with CHB. METHODS: A prospective investigation was conducted after approval by the institutional ethics committee, with 116 out of 133 patients with CHB referred for liver biopsy included and 50 patients with healthy livers selected as controls. Assessment with 2D-SWE of liver stiffness measurement (LSM) was compared with histopathological results. Cutoff values for LSM were set to determine the degree of fibrosis, and area under the receiver operating characteristic (AUROC) curve, sensitivity, and specificity were calculated. RESULTS: The optimal LSM cutoff for differentiating healthy livers from livers with CHB and any liver fibrosis was 6.485 kPa, with an AUROC of 0.927, sensitivity of 94%, and specificity of 19.8%. The optimal LSM cutoff values for F1, F2, F3, and F4 were 6.19 kPa, 6.485 kPa, 7.46 kPa, and 9.62 kPa, respectively, with corresponding AUROCs of 0.516, 0.625, 0.779, and 0.881, respectively. Comparisons of AUROCs between F1 and F3, F1 and F4, F2 and F3, and F2 and F4 were all significantly different (P = 0.0001, P < 0.0001, P = 0.0139, and P = 0.0003, respectively); comparisons of AUROCs between F1 and F2 and between F3 and F4 were not significantly different (P = 0.1232 and P = 0.2462, respectively). Comparisons of LSMs between healthy livers and F0 and between healthy livers and a combination of F0 and F1 were significantly different (P = 0.002 and P = 0.001, respectively). Comparisons of LSMs between F1 and F2 and between F3 and F4 were not significantly different (P = 0.233 and P = 0.072, respectively). Other comparisons between fibrosis score groups were significantly different (F1 and F3, P = 0.003; F1 and F4, P = 0.007; F2 and F3, P = 0.013; F2 and F4, P = 0.015). CONCLUSION: 2D-SWE using a specific diagnostic ultrasound system is effective for the assessment of severe liver fibrosis and cirrhosis, but is limited in diagnosing mild liver fibrosis.

Publisher

IOS Press

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine,Hematology,Physiology

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3