Comparison of L1 CT-attenuation and cortical thickness in predicting osteoporosis by opportunistic CT

Author:

Yao Qianqian1,Liu Jiaojiao1,Yuan Kemei1,Qiu Xiaoqian1,Wang Jiemiao1,Li Jiang1,Li Changqin1,zhu Jianzhong1,Qin Jian1

Affiliation:

1. Department of Radiology, The Second Affiliated Hospital of Shandong First Medical University, Taian, Shandong, China

Abstract

BACKGROUND: In vertebrae, the amount of cortical bone has been estimated at 30–60%, but 45–75% of axial load on a vertebral body is borne by cortical bone. OBJECTIVE: To compare the role of L1 CT-attenuation and cortical thickness in predicting osteoporosis by opportunistic CT and explore cortical thickness value in osteoporosis. METHODS: We collected data of 94 patients who underwent DXA and thoracic and/or abdominal CT to demonstrate an entire L1 for other indications in routine practice. Patients were divided into three groups according to T-score: osteoporosis, osteopenia, or normal. CT-attenuation value and cortical thickness of L1 were measured. ANOVA analysis was utilized to analyze CT-attenuation and cortical thickness among the three groups. Sensitivity, specificity, and area under the curve (AUC) predicting low BMD were determined using ROC. Pearson correlations were employed to describe relationship between L1 BMD and CT-attenuation value, BMD, as well as cortical thickness. RESULTS: The mean cortical thickness was 0.83±0.11, 0.72±0.10, and 0.64±0.09 mm for normal, osteopenia, and osteoporotic subgroups, respectively. A statistically significant difference was observed in cortical thickness and CT-attenuation value among these three subgroups. A mean CT-attenuation value threshold of > 148.7 yielded 73.0% sensitivity and 86.0% specificity for distinguishing low BMD from normal with an AUC = 0.83. Pearson correlation analysis indicated that BMD was positively correlated with CT-attenuation (r = 0.666, P < 0.001) and cortical thickness (r = 0.604, P < 0.001). CONCLUSIONS: L1 CT-attenuation and cortical thickness measured on opportunistic CT can help predict osteoporosis. Compared with cortical thickness, CT-attenuation is a more sensitive and accurate index for distinguishing low BMD from normal.

Publisher

IOS Press

Subject

Electrical and Electronic Engineering,Condensed Matter Physics,Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3