Non-convex optimization based optimal bone correction for various beam-hardening artifacts in CT imaging

Author:

Tang Shaojie123,Huang Tonggang1,Qiao Zhiwei4,Li Baolei5,Xu Yuanfei5,Mou Xuanqin6,Fan Jiulun27

Affiliation:

1. School of Automation, Xi’an University of Posts and Telecommunications, Xi’an, Shaanxi, China

2. Automatic Sorting Technology Research Center, Xi’an University of Posts and Telecommunications, State Post Bureau of the People’s Republic of China, Xi’an, Shaanxi, China

3. Xi’an Key Laboratory of Advanced Control and Intelligent Process, Xi’an, Shaanxi, China

4. School of Computer and Information Technology, Shanxi University, Taiyuan, Shanxi, China

5. Beijing Hangxing Machinery Co., Ltd., Dongcheng, Beijing, China

6. School of Electronics and Information Engineering, Xi’an Jiaotong University, Xi’an, Shaanxi, China

7. School of Communications and Information Engineering, Xi’an University of Posts and Telecommunications, Xi’an, Shaanxi, China

Abstract

Tube of X-ray computed tomography (CT) system emitting a polychromatic spectrum of photons leads to beam hardening artifacts such as cupping and streaks, while the metal implants in the imaged object results in metal artifacts in the reconstructed images. The simultaneous emergence of various beam-hardening artifacts degrades the diagnostic accuracy of CT images in clinics. Thus, it should be deeply investigated for suppressing such artifacts. In this study, data consistency condition is exploited to construct an objective function. Non-convex optimization algorithm is employed to solve the optimal scaling factors. Finally, an optimal bone correction is acquired to simultaneously correct for cupping, streaks and metal artifacts. Experimental result acquired by a realistic computer simulation demonstrates that the proposed method can adaptively determine the optimal scaling factors, and then correct for various beam-hardening artifacts in the reconstructed CT images. Especially, as compared to the nonlinear least squares before variable substitution, the running time of the new CT image reconstruction algorithm decreases 82.36% and residual error reduces 55.95%. As compared to the nonlinear least squares after variable substitution, the running time of the new algorithm decreases 67.54% with the same residual error.

Publisher

IOS Press

Subject

Electrical and Electronic Engineering,Condensed Matter Physics,Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

Reference20 articles.

1. Review of the methods for beam hardening correction in X-ray computed tomography;Zhang;CT Theory and Applications,2013

2. A beam-hardening correction method based on poly-energetic statistics in X-ray CT;Chen;CT Theory and Applications,2010

3. Estimation of energy spectra of CT system and beam-hardening correction algorithm;Ye;CT Theory and Applications,2003

4. Correction for beam hardening in computed tomography;Herman;Physics in Medicine and Biology,1979

5. A metal artifact reduction scheme in CT by a Poisson fusion sinogram based postprocessing method;Tang;Journal of X-ray Science and Technology,2021

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3