Evaluating image quality and optimal parameters for non-linear blending dual-energy computed tomography images of hepatic portal veins by blending-property-map

Author:

Lin Liying1,Han Li234,Jia Shaowei5,Zhang Tianyou6,Liu Zefeng3,Fan Jie7

Affiliation:

1. First Central Clinical College, Tianjin Medical University, Tianjin, China

2. School of Medical Imaging, Tianjin Medical University, Tianjin, China

3. Department of Radiology, Tianjin Medical University General Hospital, Tianjin, China

4. Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing, China

5. Department of Biomedical Engineering, College of Engineering, Peking University, Beijing, China

6. Department of Radiology, Chinese Academy of Medical Sciences Institute of Hematology and Blood Diseases Hospital, Tianjin, China

7. School of Linguistics, Hebei University of Technology, Tianjin, China

Abstract

BACKGROUND: Blending technology is usually used to improve quality of dual-energy computed (DECT) images. OBJECTIVES: To evaluate the blended DECT image qualities by employing the Blending-Property-Map (BP-Map) and elucidating the optimal parameters with the highest signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). METHODS: Sixty pairs of 80 kV and 140 kV CT images are blended non-linearly by four methods. Protocol A uses the fixed values of blending width (BW) and blending center (BC); Protocol B uses the values of BW =  (CThepatic portal vein – CThepatic parenchymal) / 2 and BC =  (CThepatic portal vein + CThepatic parenchymal) / 2; Protocol C uses a BW ranging from 10 to 100 HU at an interval of 10 HU and BC = (CThepatic portal vein + CThepatic parenchymal) / 2; Protocol D uses the BP-Map that covers all possible values of BW and BC. RESULTS: When using CT value of adipose tissue as noise, the calculated SNR and CNR of optimal blending width and blending center were 123.22±41.73 and 9.00±3.52, respectively, by the BP-Map in the protocol D. By employing the CT value of back muscle as noise, the SNR and CNR of the best-blended images were 75.90±14.52 and 6.39±2.37, respectively. The subjective score of protocol D was 4.88±0.12. CONCLUSIONS: Compared to traditional blending methods, the BP-Map technique can determine the optimal blending parameter and provide the best-blended images with the highest SNR and CNR.

Publisher

IOS Press

Subject

Electrical and Electronic Engineering,Condensed Matter Physics,Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation