Demonstration of quasi-real-time intrafractional motion in esophageal cancer radiotherapy provided by ExacTrac X-ray snap verification

Author:

Duan Jinghao12,Guo Ran3,Wei Wenqiang2,Zhu Jian2,Qiu Qingtao2,Zhang Ruohui4,Meng Xiangjuan5

Affiliation:

1. School of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin, China

2. Department of Radiotherapy, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, China

3. Department of Radiation Oncology, Jining NO.1 People’s Hospital, Jining, China

4. Department of Radiotherapy, the Fourth Hospital of Hebei Medical University, Shijiazhuang, China

5. Department of Clinical Laboratory, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, China

Abstract

OBJECTIVE: To investigate the following hypotheses: (1) ExacTrac X-ray Snap Verification (ET-SV) is an alternative to CBCT for positioning patients with esophageal carcinoma (EC), (2) ET-SV can detect displacement in EC patients during radiotherapy (RT) and (3) EC patients can be feasibly monitored in quasi-real-time with ET-SV during RT. METHODS: Anthropomorphic phantoms and 13 patients were included in this study. CBCT and ET-SV were both implemented before treatment delivery to detect displacement, and their correction results were compared. For the patient tests, positional correction in 3 translational directions and the yaw direction were applied using the ET-SV correction results. The residual error was detected immediately using ET-SV. Finally, to acquire the intrafractional motion, ET-SV was implemented when the gantry was at 0°, 90°, 180° and 270°, respectively. RESULTS: In phantom tests, the maximum value of the difference in displacement between the CBCT and ET systems was 1.16 mm for translation and 0.31° for yaw. According to Bland–Altman analysis of the patient test results, 5% (5/98), 5% (5/98), 5% (5/98), and 4% (4/98) of points were beyond the upper and lower limits of agreement in the AP, SI, LR and yaw directions, respectively. The mean residual error was –0.482 mm, 1.215 mm, 1.0 mm, –0.487°, 0.105°, and 0.003° in the AP, SI, LR, pitch, roll and yaw directions, respectively. The intrafractional displacement ranged from –0.21 mm to 0 mm for translation and from –0.63° to 0.21° for rotation. The mean total translational error for intrafractional motion increased from 0.47 mm to 1.14 mm during the treatment. CONCLUSION: The accuracy of ET-SV for EC RT positional correction is comparable to that of CBCT. Thus, Quasi-real-time intrafractional monitoring can be used to detect EC patient displacement during radiotherapy.

Publisher

IOS Press

Subject

Electrical and Electronic Engineering,Condensed Matter Physics,Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3