Detection of VOR dysfunction during the gaze stabilization test: Does target size matter?

Author:

Thompson-Harvey Adam1,Dutcher Charlotte E.2,Monroe Heather A.3,Sinks Belinda C.4,Goebel Joel A.4

Affiliation:

1. Department of Otolaryngology and Communication Sciences, Medical College of Wisconsin, Milwaukee, Wisconsin, USA

2. Starkey Hearing Technologies, Eden Prairie, Minnesota, USA

3. St. Louis Children’s Hospital, St. Louis, Missouri, USA

4. Dizziness and Balance Center, Department of Otolaryngology—Head and Neck Surgery, Washington University School of Medicine, Saint Louis, MO, USA

Abstract

BACKGROUND: The Gaze Stabilization Test (GST) identifies vestibulo-ocular reflex (VOR) dysfunction using a decline in target recognition with increasing head velocity, but there is no consensus on target (optotype) size above static visual acuity. OBJECTIVE: To determine the optimal optotype size above static visual acuity to be used during the GST in subjects with unilateral vestibular dysfunction and healthy individuals. METHODS: Eight subjects with unilateral vestibular dysfunction (UVD) and 19 age-matched, healthy control subjects were studied with the standard GST protocol using two optotype sizes, 0.2 and 0.3 logMAR above static visual acuity (ΔlogMAR). Maximal head velocity achieved while maintaining fixation on both optotypes was measured. Sensitivity, specificity and receiver-operator characteristic area under the curve (ROC AUC) analyses were performed to determine the optimal head velocity cut off point for each optotype, based on ability to identify the lesioned side of the UVD group from the control group. RESULTS: There was a significant difference in maximal head velocity between the UVD group and control group using 0.2 ΔlogMAR (p = 0.032) but not 0.3 ΔlogMAR (p = 0.061). While both targets produced similar specificities (90%) for distinguishing normal from subjects with UVD, 0.2 ΔlogMAR targets yielded higher sensitivity (75%) than 0.3 logMAR (63%) and accuracy (86% vs 80%, respectively) in detecting the lesioned side in subjects with UVD versus controls with maximal head velocities≤105 deg/s (p = 0.017). Furthermore, positive likelihood ratios were nearly twice as high when using 0.2 ΔlogMAR targets (+ LR 10) compared to 0.3 ΔlogMAR (+ LR 6.3). CONCLUSION: The 0.2 ΔlogMAR optotype demonstrated significantly superior identification of subjects with UVD, better sensitivity and positive likelihood ratios than 0.3 ΔlogMAR for detection of VOR dysfunction. Using a target size 0.2logMAR above static visual acuity (ΔlogMAR) during GST may yield better detection of VOR dysfunction to serve as a baseline for gaze stabilization rehabilitation therapy.

Publisher

IOS Press

Subject

Neurology (clinical),Sensory Systems,Otorhinolaryngology,General Neuroscience

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3