Estimation of dabigatran plasma concentrations in the perioperative setting

Author:

Dincq Anne-Sophie,Hjemdahl Paul,Rönquist-Nii Yuko,Pohanka Anton,Gourdin Maximilien,Chatelain Bernard,Dogné Jean-Michel,Mullier François,Douxfils Jonathan,Lessire Sarah

Abstract

SummaryThe perioperative management of dabigatran is challenging, and recommendations based on activated partial thromboplastin time (aPTT) and thrombin time (TT) are unsatisfactory. Dedicated coagulation tests have limitations at plasma concentrations < 50 ng/ml. Therefore, a more sensitive test, which is available 24/7, is required. It was the aim of this study to investigate the performance of the Hemoclot Thrombin Inhibitors® LOW (HTI LOW) kit, a diluted thrombin time, and the STA® – ECA II (ECA-II) kit, a chromogenic variant of the ecarin clotting time, that were developed to measure low dabigatran concentrations, compared to reference dabigatran analysis by liquid chromatography tandem mass-spectrometry (LC-MS/MS). This study included 33 plasma samples from patients treated with dabigatran etexilate who had plasma concentrations < 200 ng/ml. HTI LOW and ECA-II were performed along with HTI, aPTT (STA®-C. K.Prest® and SynthasIL ®) and TT (STA® – Thrombin). All procedures were performed according to recommendations by the manufacturers. Linear (or curvilinear) correlations and Bland-Altman analyses were calculated. For free dabigatran concentrations < 50 ng/ml, the R2 of linear correlations were 0.69, 0.84 and 0.61, with HTI, HTI LOW and ECA-II, respectively. The R2 for TT, STA®-C. K.Prest® and SynthasIL® were 0.67, 0.42 and 0.15. For HTI, HTI LOW and ECA-II, Bland-Altman analyses revealed mean differences of –6 ng/ml (95 %CI: –25–14 ng/ml), 1 ng/ml (95 %CI: –18–19 ng/ml) and –1 ng/ml (95 %CI: –25–23 ng/ml), demonstrating that tests dedicated to measuring low concentrations are more accurate than HTI. In conclusion, the use of HTI LOW or ECA-II to assess low plasma dabigatran concentrations is supported by our findings.

Publisher

Georg Thieme Verlag KG

Subject

Hematology

Cited by 55 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3