Initial presentation of scintigraphic changes during the first episode of acute pyelonephritis in children

Author:

Smokvina A.,Girotto N.,Licul V.,Grbac-Ivanković S.

Abstract

Summary 99mTc-DMSA scintigraphy is generally accepted as the method of choice for detecting renal parenchymal damage in pyelonephritis. 99mTc-MAG3 dynamic scintigraphy is not routinely used for this purpose. The aim of this study was to evaluate the MAG3 scintigraphic presentation in the acute phase of pyelonephritis in children and re-evaluate them at least 6 months later, as well as to establish whether a MAG3 in the parenchymal phase is as reliable and sensitive in the detection of a renal parenchymal damage as the DMSA. Patients, methods: The MAG3 scintigraphic pattern was evaluated during the first episode of acute pyelonephritis in 31 children (median age: 2.5 years) and compared to the DMSA scan. The scintigraphy was performed on the same day with both radiopharmaceuticals. After at least 6 months the whole procedure was repeated on 28 patients. A scoring system was designed to evaluate the parenchymal lesions, and categorize them as positive or equivocal. The findings on the initial scans were compared to those obtained in the follow up studies. Results: When all lesions (equivocal + positive) were analysed, MAG3 sensitivity was 98%, and specificity 78%, while for positive lesions only, the values were 83 and 100%, respectively. The average acute severity score was significantly lower for both MAG3 and DMSA then the follow up score (p <0.0001). These results corresponded to a clinical convalescence, which was observed in 26/28 children in the follow up. Conclusion: With the MAG3 scintigraphy a reliable semi quantitative and qualitative detection of the renal inflammatory lesions can be obtained in acute pyelonephritis, as well as their recovery, thus obviating the need for a DMSA scan. Moreover, the duration of the MAG3 procedure is shorter, enabling the visualization of the entire collecting system as well, while the radiation exposure is approximately a half of that delivered by the DMSA scan.

Publisher

Georg Thieme Verlag KG

Subject

Radiology Nuclear Medicine and imaging,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3