Face Masks at the Gymnasium: Physiological Responses and Mechanical Performance Are Not Compromised by Wearing Surgical or Filtering Facepiece 2 Masks in Healthy Subjects

Author:

Rial-Vázquez Jessica1,Nine Iván1,Guerrero-Moreno Jose María1,Rúa-Alonso María1,Fariñas Juan1,Márquez Gonzalo2,Giráldez-García Manuel Avelino1,Méndez-Bouza Kevin Yoel2,López-Pillado Hugo2,Coutado-Sánchez Etham2,Losada-Rodríguez Alejandro2,Iglesias-Soler Eliseo1ORCID

Affiliation:

1. Performance and Health Group, Department of Physical Education and Sport, Faculty of Sports Sciences and Physical Education, University of A Coruna, A Coruña, Spain; and

2. Faculty of Sports Sciences and Physical Education, University of A Coruna, A Coruña, Spain

Abstract

Abstract Rial-Vázquez, J, Nine, I, Guerrero-Moreno, JM, Rúa-Alonso, M, Fariñas, J, Márquez, G, Giráldez-García, MA, Méndez-Bouza, KY, López-Pillado, H, Coutado-Sánchez, E, Losada-Rodríguez, A, and Iglesias-Soler, E. Face masks at the gym: physiological responses and mechanical performance are not compromised by wearing surgical or filtering facepiece 2 masks in healthy subjects. J Strength Cond Res 37(7): 1404–1410, 2023—This study explored the effects of wearing 2 types of face masks on mechanical performance and physiological responses during high-intensity resistance exercise. Twelve healthy men performed 3 workout protocols in a randomized order: wearing a surgical or filtering facepiece 2 (FFP2) mask or without a mask. Each workout consisted of 3 sets of 10 repetitions of bench press (BP) and parallel squat (SQ) with a 12 repetition maximum load, including 2 minutes of recovery between sets and exercises. Mechanical performance was evaluated through the mean propulsive velocity and the number of repetitions completed during each session. Physiological responses were the oxygen saturation (SpO2), blood lactate concentration, heart rate (HR), and HR variability. Perceived exertion was recorded after each set, and The Beck Anxiety Inventory scale was completed at the end of each workout. The number of repetitions completed and the session mean propulsive velocity {(BP [m·s−1]: surgical: 0.35 ± 0.05; FFP2: 0.36 ± 0.04; nonmask: 0.38 ± 0.06) and (SQ: surgical: 0.43 ± 0.05; FFP2: 0.40 ± 0.07; nonmask: 0.41 ± 0.05)} were similar between conditions (p > 0.05). Heart rate recorded during sessions was similar across conditions: surgical: 119 ± 14, FFP2: 117 ± 13, and nonmask: 118 ± 10 bpm (p = 0.919). Face masks had no effect on SpO2, blood lactate concentration, HR variability, perceived exertion, and anxiety values (p > 0.05). Face masks do not compromise strength performance, physiological parameters, and perceived comfort of young and healthy individuals during a high-intensity resistance training session.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine,General Medicine

Reference28 articles.

1. Triggering of sudden death from cardiac causes by vigorous exertion;Albert;N Engl J Med,2000

2. Ventilatory efficiency during constant-load test at lactate threshold intensity: Endurance versus resistance exercises;Albesa-Albiol;PLoS One,2019

3. American College of Sports Medicine. General principles of exercise prescription;Guidelines for Exercise Testing and Prescription, 11th Ed. American College of Sports Medicine.,2021

4. Restrictive breathing mask reduces repetitions to failure during a session of lower-body resistance exercise;Andre;J Strength Cond Res,2018

5. Effectiveness of mask wearing to control community spread of SARS-CoV-2;Brooks;JAMA,2021

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3