Effect of 3 Different Set Configurations on Kinematic Variables and Internal Loads During a Power Snatch Session

Author:

Nagatani Tsuyoshi1ORCID,Kendall Kristina L.1,Guppy Stuart N.1,Poon Wayne C.K.1,Haff G. Gregory12

Affiliation:

1. School of Medical and Health Science, Centre for Human Performance, Edith Cowan University, Western Australia, Australia; and

2. University of Salford, Salford, United Kingdom

Abstract

Abstract Nagatani, T, Kendall, KL, Guppy, SN, Poon, WCK, and Haff, GG. Effect of 3 different set configurations on kinematic variables and internal loads during a power snatch session. J Strength Cond Res 37(10): 1929–1938, 2023—The aim of this study was to investigate the effect of 3 different set configurations on kinematic variables and internal loads during multiple sets performed with the power snatch. Ten strength-power athletes with at least 6 months of training experience performing the power snatch participated in this study, which consisted of 3 experimental protocols performed in a randomized repeated-measures design. The 3 protocols involved performing the power snatch for 3 sets of 5 repetitions at an average load of 75% 1 repetition maximum with a traditional (TRAD), cluster (CLU), or ascending cluster (A-CLU) protocol, where the training load was progressively increased across the set. Kinematic variables and internal loads (heart rate, blood lactate, and rate of perceived exertion) were measured during each protocol. The athletes maintained peak velocity (PV) and peak power (PP) and exhibited lower internal loads during CLU sets when compared with TRAD sets, whereas they displayed significant decreases in PV during TRAD sets. However, there were no statistically significant differences in PV and PP responses between the TRAD and CLU protocol. The athletes exhibited a significant decrease in PV, whereas PP was increased across each set in the A-CLU protocol, with lower internal loads observed compared with the TRAD protocol. Overall, the training loads used in this study do not appear to maximize the benefits of using CLU set during 3 sets of power snatches performed for 5 repetitions. In addition, A-CLU sets may potentially be useful as a means of maximizing the power output of the athlete.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3