Countermovement Jump Force-Time Curve Analyses: Reliability and Comparability Across Force Plate Systems

Author:

Merrigan Justin J.12,Strang Adam1,Eckerle Jason1,Mackowski Nick1,Hierholzer Kaela1,Ray Nicole T.13,Smith Roger1,Hagen Joshua A.12,Briggs Robert A.1

Affiliation:

1. STRONG Lab, Air Force Research Laboratory, Wright-Patterson Air Force Base (WPAFB), Ohio;

2. Human Performance Collaborative, Office of Research, The Ohio State University, Ohio; and

3. Infoscitex, Inc., WPAFB, Ohio

Abstract

Abstract Merrigan, JJ, Strang, A, Eckerle, J, Mackowski, N, Hierholzer, K, Ray, NT, Smith, R, Hagen, JA, and Briggs, RA. Countermovement jump force-time curve analyses: reliability and comparability across force plate systems. J Strength Cond Res 38(1): 30–37, 2024—Considering the growing prevalence of commercial force plates providing automated force-time analyses, understanding levels of agreement across force plate systems is warranted. Countermovement jump (CMJ) metrics across Vald ForceDecks (FD), Hawkin Dynamics (HD), and Sparta Science (SS) force plate systems were compared. Twenty-two subjects completed CMJ testing (∼128 comparisons) on each force plate system separately with rest between jumps. Baseline testing occurred 3 times and demonstrated poor test-retest reliability for modified reactive strength index (mRSI) and rate of force development (RFD). ForceDecks and HD comparisons yielded acceptable agreement for concentric/propulsive relative force and net impulse, jump height, eccentric/braking RFD, and mRSI, but systematic and proportionate bias existed for RFD. Sparta Science jump height and reactive strength index (RSI) demonstrated systematic overestimations compared with HD and FD, but jump height had acceptable agreement according to concordance correlation coefficients (CCC = 0.92–0.95). Agreement between SS load (eccentric RFD) and HD braking RFD was acceptable (CCC = 0.91), whereas agreement between SS load and FD deceleration RFD was considered acceptable (CCC = 0.81–0.87) but demonstrated systematic and proportionate bias. ForceDecks (CCC = 0.89) and HD (CCC = 0.85) average relative concentric/propulsive force yielded acceptable agreement with SS explode (average relative concentric force), but SS explode demonstrated systematically lower values than FD and HD. Sparta Science drive (concentric impulse) yielded acceptable agreement with HD relative propulsive impulse (CCC = 0.85), but not FD concentric impulse. Human performance practitioners need to be aware of inconsistencies among testing procedures and analyses across force plate systems, such as differences in metric definitions and units of measurement, before making comparisons across systems.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3