Reliability, Usefulness, and Validity of Field-Based Vertical Jump Measuring Devices

Author:

Comyns Thomas M.12,Murphy Jennifer3,O'Leary Dylan1

Affiliation:

1. Department of Physical Education and Sport Sciences, University of Limerick, Limerick, Ireland;

2. Sport and Human Performance Research Centre, University of Limerick, Limerick, Ireland; and

3. Centre of Applied Science for Health, Technological University Dublin, Dublin, Ireland

Abstract

Abstract Comyns, TM, Murphy, J, and O’Leary, D. Reliability, usefulness, and validity of field-based vertical jump measuring devices. J Strength Cond Res 37(8): 1594–1599, 2023—The purpose of this study was to examine the test-retest reliability, usefulness, and validity of field-based devices, in determining jump height (JH) during a countermovement jump (CMJ). Twenty-one male (22.8 ± 2.4 years; 1.82 ± 0.07 m; 86.0 ± 10.4 kg) and 7 female field sport athletes (20.5 ± 1.5 years; 1.65 ± 0.06 m; 65.4 ± 7.2 kg) performed 3 CMJs with data simultaneously recorded using a force plate (criterion measure), Optojump, Output Capture, and Push-Band 2.0. Reliability was determined by intraclass correlation (ICC) and coefficient of variation (CV) analyses. Usefulness was assessed by comparing typical error (TE) with the smallest worthwhile change (SWC), and the validity analyses involved repeated measures analysis of variance with post hoc analysis, Pearson correlation coefficient (r), coefficient of determination, and Bland-Altman 95% limits of agreement analyses. All 3 field-based devices were deemed reliable in assessing CMJ height as the respective ICCs ≥ 0.80 and the CV ≤ 10%. Only the Optojump and Output Capture devices were rated as “good” at detecting the SWC in performance (Optojump SWC: 1.44 > TE: 1.04; Output Capture SWC: 1.47 > TE: 1.05). The Output Capture device demonstrated acceptable validity for CMJ height assessment, whereas the Push-Band 2.0 showed systematic bias when compared with the criterion force plate data. Systematic difference was also evident for the Optojump potentially due to the optical switching-cell position on the Optojump. Although all 3 devices showed excellent reliability, the Optojump and Output Capture devices offer practitioners a cost effective, reliable, and valid method of assessing the smallest worthwhile change in CMJ performance in an applied setting.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3