Abstract
This article discusses the energy efficiency of plastic windows with the filling the space between panes by dry air, argon, krypton, xenon and SF6 gas. Numerical calculation of reduced resistance to heat transfer of window blocks with different 4 configurations of the transparent part were performed using Them 7.6 and Window 7.6 software. Finally, the results of this work can be used for developing recommendations of using the window block configurations filled with air and gases other than.
Publisher
Novosibirsk State University of Architecture and Civil Engineering (Sibstrin)
Subject
General Earth and Planetary Sciences,General Environmental Science