<p>Today’s world is very much concerned to reduce green house gas emission from the conventional thermal power plants as cutting down emissions from transport and heating sector may not be realistic in the near future. To reduce pollution from electrical power sources, the world is now marching towards usage of renewable energy sources (RESs). These sources being small in capacity are mostly connected at the distribution voltage level. This indirectly reduces transmission and distribution losses as the sources are around the load. This distribution system having small scale energy sources is called as a microgrid or active distribution network. Microgrid operates generally in a grid connected mode. However, circumstances such as fault, voltage sag and large frequency oscillations in the main grid may force the active distribution network to be disconnected from the main grid and operate as an isolated microgrid . During this isolation there will be change in power output from the controllable microsources which are to be regulated properly to have a stable operation in regard to power balance and frequency of operation within the isolated microgrid. An autonomous isolated microgrid comprising both controllable &amp; uncontrollable sources. Like solar, wind, diesel generator(DG), aqua electrolyzer(AE), fuel cell(FC),  a battery energy storage system(BESS), and fly wheel(FW) are considered. Solar, wind, DG and FC are power generating source &amp; BESS, FW, AE as energy storage element. The generated hydrogen by an AE is used as fuel for a FC. The power system frequency deviates for the sudden change in load demand and the real power generation. The output power of DG,  FC, BESS, FW and power absorbed by AE is regulated by using controller such that frequency of the system is controlled. Controller used is proportional plus integral plus derivative (PID). Load Disturbance Rejection(LDR) is used for tuning of controller gains of the proposed hybrid system. This uses the chien-hornes-resnick(CHR) setting with 20% overshoot. Design of p-f droop(frequency regulation parameter) for different controllable source in microgrid using bode plot stability criterion. The system response with Modified LDR based controller, LDR based controller and classical controller are compared. Investigation shows that Modified LDR based controller gives best response amongst these three methods.</p>

Publisher

Institute of Advanced Engineering and Science

Subject

Electrical and Electronic Engineering,Control and Optimization,Computer Networks and Communications,Hardware and Architecture,Information Systems,Signal Processing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3