An observational study to assess if automated diabetic retinopathy image assessment software can replace one or more steps of manual imaging grading and to determine their cost-effectiveness

Author:

Tufail Adnan1,Kapetanakis Venediktos V2,Salas-Vega Sebastian3,Egan Catherine1,Rudisill Caroline3,Owen Christopher G2,Lee Aaron1,Louw Vern1,Anderson John4,Liew Gerald1,Bolter Louis4,Bailey Clare5,Sadda SriniVas6,Taylor Paul7,Rudnicka Alicja R2

Affiliation:

1. National Institute for Health Research Moorfields Biomedical Research Centre, Moorfields Eye Hospital, London, UK

2. Population Health Research Institute, St George’s, University of London, London, UK

3. Department of Social Policy, LSE Health, London School of Economics and Political Science, London, UK

4. Homerton University Hospital Foundation Trust, London, UK

5. Bristol Eye Hospital, Bristol, UK

6. Doheny Eye Institute, Los Angeles, CA, USA

7. Centre for Health Informatics & Multiprofessional Education (CHIME), Institute of Health Informatics, University College London, London, UK

Abstract

Background Diabetic retinopathy screening in England involves labour-intensive manual grading of retinal images. Automated retinal image analysis systems (ARIASs) may offer an alternative to manual grading. Objectives To determine the screening performance and cost-effectiveness of ARIASs to replace level 1 human graders or pre-screen with ARIASs in the NHS diabetic eye screening programme (DESP). To examine technical issues associated with implementation. Design Observational retrospective measurement comparison study with a real-time evaluation of technical issues and a decision-analytic model to evaluate cost-effectiveness. Setting A NHS DESP. Participants Consecutive diabetic patients who attended a routine annual NHS DESP visit. Interventions Retinal images were manually graded and processed by three ARIASs: iGradingM (version 1.1; originally Medalytix Group Ltd, Manchester, UK, but purchased by Digital Healthcare, Cambridge, UK, at the initiation of the study, purchased in turn by EMIS Health, Leeds, UK, after conclusion of the study), Retmarker (version 0.8.2, Retmarker Ltd, Coimbra, Portugal) and EyeArt (Eyenuk Inc., Woodland Hills, CA, USA). The final manual grade was used as the reference standard. Arbitration on a subset of discrepancies between manual grading and the use of an ARIAS by a reading centre masked to all grading was used to create a reference standard manual grade modified by arbitration. Main outcome measures Screening performance (sensitivity, specificity, false-positive rate and likelihood ratios) and diagnostic accuracy [95% confidence intervals (CIs)] of ARIASs. A secondary analysis explored the influence of camera type and patients’ ethnicity, age and sex on screening performance. Economic analysis estimated the cost per appropriate screening outcome identified. Results A total of 20,258 patients with 102,856 images were entered into the study. The sensitivity point estimates of the ARIASs were as follows: EyeArt 94.7% (95% CI 94.2% to 95.2%) for any retinopathy, 93.8% (95% CI 92.9% to 94.6%) for referable retinopathy and 99.6% (95% CI 97.0% to 99.9%) for proliferative retinopathy; and Retmarker 73.0% (95% CI 72.0% to 74.0%) for any retinopathy, 85.0% (95% CI 83.6% to 86.2%) for referable retinopathy and 97.9% (95% CI 94.9 to 99.1%) for proliferative retinopathy. iGradingM classified all images as either ‘disease’ or ‘ungradable’, limiting further iGradingM analysis. The sensitivity and false-positive rates for EyeArt were not affected by ethnicity, sex or camera type but sensitivity declined marginally with increasing patient age. The screening performance of Retmarker appeared to vary with patient’s age, ethnicity and camera type. Both EyeArt and Retmarker were cost saving relative to manual grading either as a replacement for level 1 human grading or used prior to level 1 human grading, although the latter was less cost-effective. A threshold analysis testing the highest ARIAS cost per patient before which ARIASs became more expensive per appropriate outcome than human grading, when used to replace level 1 grader, was Retmarker £3.82 and EyeArt £2.71 per patient. Limitations The non-randomised study design limited the health economic analysis but the same retinal images were processed by all ARIASs in this measurement comparison study. Conclusions Retmarker and EyeArt achieved acceptable sensitivity for referable retinopathy and false-positive rates (compared with human graders as reference standard) and appear to be cost-effective alternatives to a purely manual grading approach. Future work is required to develop technical specifications to optimise deployment and address potential governance issues. Funding The National Institute for Health Research (NIHR) Health Technology Assessment programme, a Fight for Sight Grant (Hirsch grant award) and the Department of Health’s NIHR Biomedical Research Centre for Ophthalmology at Moorfields Eye Hospital and the University College London Institute of Ophthalmology.

Funder

Health Technology Assessment programme

Fight for Sight

Department of Health’s NIHR Biomedical Research Centre for Ophthalmology at Moorfields Eye Hospital and the University College London Institute of Ophthalmology

Publisher

National Institute for Health Research

Subject

Health Policy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3