A programme of studies including assessment of diagnostic accuracy of school hearing screening tests and a cost-effectiveness model of school entry hearing screening programmes

Author:

Fortnum Heather1,Ukoumunne Obioha C2,Hyde Chris3,Taylor Rod S3,Ozolins Mara1,Errington Sam1,Zhelev Zhivko2,Pritchard Clive4,Benton Claire5,Moody Joanne6,Cocking Laura7,Watson Julian8,Roberts Sarah4

Affiliation:

1. National Institute for Health Research, Nottingham Hearing Biomedical Research Unit, Hearing and Otology Group, Division of Clinical Neuroscience, School of Medicine, University of Nottingham, Nottingham, UK

2. National Institute for Health Research, Collaborations for Leadership in Applied Health Research and Care South West Peninsula, University of Exeter Medical School, Exeter, UK

3. Institute of Health Research, University of Exeter Medical School, Exeter, UK

4. Optimity Advisors, Kemp House, London, UK

5. Nottingham Audiology Services, Nottingham University Hospitals, Nottingham, UK

6. Cambridgeshire Community Services, Community Child Health, Ida Darwin Hospital, Fulbourn, Cambridge, UK

7. Peninsula Clinical Trials Unit, Plymouth University Peninsula Schools of Medicine and Dentistry, Plymouth, UK

8. Parent representative, Nottingham, UK

Abstract

BackgroundIdentification of permanent hearing impairment at the earliest possible age is crucial to maximise the development of speech and language. Universal newborn hearing screening identifies the majority of the 1 in 1000 children born with a hearing impairment, but later onset can occur at any time and there is no optimum time for further screening. A universal but non-standardised school entry screening (SES) programme is in place in many parts of the UK but its value is questioned.ObjectivesTo evaluate the diagnostic accuracy of hearing screening tests and the cost-effectiveness of the SES programme in the UK.DesignSystematic review, case–control diagnostic accuracy study, comparison of routinely collected data for services with and without a SES programme, parental questionnaires, observation of practical implementation and cost-effectiveness modelling.SettingSecond- and third-tier audiology services; community.ParticipantsChildren aged 4–6 years and their parents.Main outcome measuresDiagnostic accuracy of two hearing screening devices, referral rate and source, yield, age at referral and cost per quality-adjusted life-year.ResultsThe review of diagnostic accuracy studies concluded that research to date demonstrates marked variability in the design, methodological quality and results. The pure-tone screen (PTS) (Amplivox, Eynsham, UK) and HearCheck (HC) screener (Siemens, Frimley, UK) devices had high sensitivity (PTS ≥ 89%, HC ≥ 83%) and specificity (PTS ≥ 78%, HC ≥ 83%) for identifying hearing impairment. The rate of referral for hearing problems was 36% lower with SES (Nottingham) relative to no SES (Cambridge) [rate ratio 0.64, 95% confidence interval (CI) 0.59 to 0.69;p < 0.001]. The yield of confirmed cases did not differ between areas with and without SES (rate ratio 0.82, 95% CI 0.63 to 1.06;p = 0.12). The mean age of referral did not differ between areas with and without SES for all referrals but children with confirmed hearing impairment were older at referral in the site with SES (mean age difference 0.47 years, 95% CI 0.24 to 0.70 years;p < 0.001). Parental responses revealed that the consequences to the family of the referral process are minor. A SES programme is unlikely to be cost-effective and, using base-case assumptions, is dominated by a no screening strategy. A SES programme could be cost-effective if there are fewer referrals associated with SES programmes or if referrals occur more quickly with SES programmes.ConclusionsA SES programme using the PTS or HC screener is unlikely to be effective in increasing the identified number of cases with hearing impairment and lowering the average age at identification and is therefore unlikely to represent good value for money. This finding is, however, critically dependent on the results of the observational study comparing Nottingham and Cambridge, which has limitations. The following are suggested: systematic reviews of the accuracy of devices used to measure hearing at school entry; characterisation and measurement of the cost-effectiveness of different approaches to the ad-hoc referral system; examination of programme specificity as opposed to test specificity; further observational comparative studies of different programmes; and opportunistic trials of withdrawal of SES programmes.Trial registrationCurrent Controlled Trials ISRCTN61668996.FundingThis project was funded by the NIHR Health Technology Assessment programme and will be published in full inHealth Technology Assessment; Vol. 20, No. 36. See the NIHR Journals Library website for further project information.

Funder

Health Technology Assessment programme

Publisher

National Institute for Health Research

Subject

Health Policy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3