Nocturnal temperature-controlled laminar airflow device for adults with severe allergic asthma: the LASER RCT
-
Published:2019-06
Issue:29
Volume:23
Page:1-140
-
ISSN:1366-5278
-
Container-title:Health Technology Assessment
-
language:en
-
Short-container-title:Health Technol Assess
Author:
Kapoor Melissa1ORCID, Storrar Will2ORCID, Balls Lara2ORCID, Brown Thomas P2ORCID, Mansur Adel3ORCID, Hedley Emma4ORCID, Jones Tom2ORCID, Roberts Claire2ORCID, Shirkey Beverly5ORCID, Dutton Susan5ORCID, Luengo-Fernandez Ramon6ORCID, Little Matthew6ORCID, Dewey Ann7ORCID, Marshall Sue2ORCID, Fogg Carole27ORCID, Boughton Keith2, Rahman Najib4ORCID, Yu Ly-Mee8ORCID, Bradding Peter9ORCID, Howarth Peter10ORCID, Chauhan Anoop J27ORCID
Affiliation:
1. South East Health Technologies Alliance, Henfield, UK 2. Portsmouth Hospitals NHS Trust, Respiratory Department, Portsmouth, UK 3. Heartlands Hospital, Respiratory Department, Birmingham, UK 4. Oxford Respiratory Trials Unit, University of Oxford, Oxford, UK 5. Oxford Clinical Trials Research Unit, Centre for Statistics in Medicine, University of Oxford, Oxford, UK 6. Health Economics Research Centre, University of Oxford, Oxford, UK 7. School of Health Sciences and Social Work, University of Portsmouth, Portsmouth, UK 8. Primary Care Trials Unit, Nuffield Department of Primary Care Health, University of Oxford, Oxford, UK 9. Leicester Respiratory Biomedical Research Unit, Leicester, UK 10. University Hospital Southampton NHS Foundation Trust, Respiratory Department, Southampton, UK
Abstract
Background
Severe asthma exacerbations are costly to patients and the NHS, and occur frequently in severely allergic patients.
Objective
To ascertain whether or not nocturnal temperature-controlled laminar airflow (TLA) device usage over 12 months can reduce severe exacerbations and improve asthma control and quality of life compared with a placebo device, while being cost-effective and acceptable to adults with severe allergic asthma.
Design
A pragmatic, multicentre, randomised, double-blind, placebo-controlled, parallel-group, superiority trial with qualitative interviews. The trial included an internal pilot with qualitative focus groups.
Setting
Fourteen hospitals in the UK that manage patients with severe asthma.
Participants
Adults (16–75 years) with severe, poorly controlled, exacerbation-prone asthma despite high-intensity treatment, and who are sensitised to a perennial indoor aeroallergen.
Intervention
Nocturnal, home-based TLA treatment using an Airsonett® (Airsonett AB, Ängelholm, Sweden) device. The comparator was a placebo device that was identical to the active device except that it did not deliver the laminar airflow. Participants were allocated 1 : 1 to TLA therapy or placebo, minimised by site, origin of case, baseline severe exacerbation frequency, maintenance oral corticosteroid use and pre-bronchodilator forced expiratory volume in 1 second.
Main outcome measures
Primary outcome – frequency of severe asthma exacerbations occurring within the 12-month follow-up period, defined as worsening of asthma requiring systemic corticosteroids [≥ 30 mg of prednisolone or equivalent daily (or ≥ 50% increase in dose if on maintenance dose of ≥ 30 mg of prednisolone)] for ≥ 3 days. Secondary outcomes – changes in asthma control, lung function, asthma-specific and global quality of life for participants, adherence to the intervention, device acceptability, health-care resource use and cost-effectiveness.
Results
Between May 2014 and January 2016, 489 patients consented to participate in the trial, of whom 249 failed screening and 240 were randomised (n = 119 in the treatment group and n = 121 in the placebo group); all were analysed. In total, 202 participants (84%) reported use of the device for 9–12 months. Qualitative analyses showed high levels of acceptability. The mean [standard deviation (SD)] rate of severe exacerbations did not differ between groups [active 1.39 (1.57), placebo 1.48 (2.03); risk ratio 0.92, 95% CI 0.66 to 1.27; p = 0.616]. There were no significant differences in secondary outcomes for lung function, except for a reduction in mean daily peak expiratory flow [mean (SD) difference 14.7 l/minute (7.35 l/minute), 95% CI 0.32 to 29.1 l/minute; p = 0.045) for those in the active device group. There were no differences in asthma control or airway inflammation and no serious harms related to the device. No significant difference between the groups in quality-adjusted life-years gained over 1 year was observed. In addition, there was no difference in generic or disease-specific health-related quality of life overall, although statistically significant higher quality of life at month 6 was observed. Increases in quality of life were not sufficient to offset the annual costs associated with use of the TLA device.
Limitations
Missing outcome data could have resulted in an underestimation of exacerbations and rendered the study inconclusive.
Conclusions
Within the limits of the data, no consistent benefits of the active device were demonstrated, and the differences observed were not sufficient to make the device cost-effective. The types of patients who may benefit from the TLA device, and the reasons for large reductions in exacerbation frequency in severe asthma trials, which also incorporate other methods of recording exacerbations, need to be explored.
Trial registration
Current Controlled Trials ISRCTN46346208.
Funding
This project was funded by the NIHR Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 23, No. 29. See the NIHR Journals Library website for further project information.
Funder
Health Technology Assessment programme
Publisher
National Institute for Health Research