Continuous glucose monitoring in extremely preterm infants in intensive care: the REACT RCT and pilot study of ‘closed-loop’ technology

Author:

Beardsall Kathryn12ORCID,Thomson Lynn1ORCID,Guy Catherine1ORCID,Bond Simon3ORCID,Allison Annabel3ORCID,Pantaleo Beatrice3ORCID,Petrou Stavros45ORCID,Kim Sungwook45ORCID,Dunger David16ORCID,Hovorka Roman6ORCID

Affiliation:

1. Department of Paediatrics, University of Cambridge, Cambridge, UK

2. Neonatal Intensive Care Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK

3. Cambridge Clinical Trials Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK

4. Warwick Clinical Trials Unit, Warwick Medical School, University of Warwick, Coventry, UK

5. Nuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK

6. University of Cambridge Metabolic Research Laboratories, Wellcome Trust-MRC Institute of Metabolic Science, Cambridge, UK

Abstract

Background Hyperglycaemia and hypoglycaemia are common in preterm infants and are associated with increased mortality and morbidity. Continuous glucose monitoring is widely used to target glucose control in adults and children, but not in neonates. Objective To evaluate the role of continuous glucose monitoring in the preterm infant. Design The REAl-time Continuous glucose moniToring in neonatal intensive care project combined (1) a feasibility study, (2) a multicentre randomised controlled trial and (3) a pilot of ‘closed-loop’ continuous glucose monitoring. The feasibility study comprised a single-centre study (n = 20). Eligibility criteria included a birthweight ≤ 1200 g and aged ≤ 48 hours. Continuous glucose monitoring was initiated to support glucose control. The efficacy and safety outcomes guided the design of the randomised controlled trial. The randomised controlled trial comprised a European multicentre trial (n = 182). Eligibility criteria included birthweight ≤ 1200 g and aged ≤ 24 hours. Exclusion criteria included any lethal congenital abnormality. Continuous glucose monitoring was initiated to support glucose control within 24 hours of birth. In the intervention group, the continuous glucose monitoring sensor provided real-time data on glucose levels, which guided clinical management. In control infants, the continuous glucose monitoring data were masked, and glucose level was managed in accordance with standard clinical practice and based on the blood glucose levels. The primary outcome measure was the percentage of time during which the sensor glucose level was within the target range of 2.6–10 mmol/l. Secondary outcome measures included mean sensor glucose level, the percentage of time during which the sensor glucose level was within the target range of 4–8 mmol/l, the percentage of time during which the sensor glucose level was in the hyperglycaemic range (i.e. > 15 mmol/l) and sensor glucose level variability. Safety outcomes included hypoglycaemia exposure. Acceptability assessment and health economic analyses were carried out and further exploratory health outcomes were explored. The mean percentage of time in glucose target range of 2.6–10 mmol/l was 9% higher in infants in the continuous glucose monitoring group (95% confidence interval 3% to 14%; p = 0.002), and the mean time in the target range of 4–8 mmol/l was 12% higher in this group (95% confidence interval 4% to 19%; p = 0.004). There was no difference in the number of episodes of hypoglycaemia. Exploratory outcomes showed a reduced risk of necrotising enterocolitis in the intervention arm (odds ratio 0.33, 95% confidence interval 0.13 to 0.78; p = 0.01). Health economic analyses demonstrated that continuous glucose monitoring was cost-effective on the basis of the cost per additional case of adequate glucose control between 2.6 and 10 mmol/l. The ‘closed-loop’ study was a single-center pilot study, with eligibility criteria including a birthweight of ≤ 1200 g and aged ≤ 48 hours. Infants underwent continuous glucose monitoring for the first week of life (n = 21), with those in the intervention group receiving closed-loop insulin delivery between 48 and 72 hours of age. The primary outcome of percentage of time in the target range (i.e. sensor glucose 4–8 mmol/l) increased from a median of 26% (interquartile range 6–64%) to 91% (interquartile range 78–99%) during closed-loop insulin delivery (p < 0.001). Limitations These studies have not defined the optimal targets for glucose control or the best strategies to achieve them in these infants. Future work Studies are needed to evaluate the longer-term impact of targeting glucose control on clinical outcomes. Conclusions Continuous glucose monitoring in extremely preterm infants can improve glucose control, with closed-loop insulin delivery having further potential to target glucose levels. Staff and parents felt that the use of continuous glucose monitoring improved care and the results of the health economic evaluation favours the use of continuous glucose monitoring. Trial registration Current Controlled Trials ISRCTN12793535. Funding This project was funded by the Efficacy and Mechanism Evaluation (EME) programme, a MRC and National Institute for Health Research (NIHR) partnership. This will be published in full in Efficacy and Mechanism Evaluation; Vol. 8, No. 16. See the NIHR Journals Library website for further project information. Medtronic plc provided some MiniMed™ 640G systems and Nova Biomedical (Waltham, MA, USA) provided point-of-care devices.

Funder

Efficacy and Mechanism Evaluation programme

Medical Research Council

Medtronic

Nova Biomedical

Publisher

National Institute for Health Research

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3