Implantable cardiac monitors to detect atrial fibrillation after cryptogenic stroke: a systematic review and economic evaluation

Author:

Edwards Steven J1ORCID,Wakefield Victoria1ORCID,Jhita Tracey1ORCID,Kew Kayleigh1ORCID,Cain Peter1ORCID,Marceniuk Gemma1ORCID

Affiliation:

1. British Medical Journal (BMJ) Technology Assessment Group, London, UK

Abstract

Background Cryptogenic stroke is a stroke for which no cause is identified after standard diagnostic tests. Long-term implantable cardiac monitors may be better at diagnosing atrial fibrillation and provide an opportunity to reduce the risk of stroke recurrence with anticoagulants. Objectives The objectives were to assess the diagnostic test accuracy, clinical effectiveness and cost-effectiveness of three implantable monitors [BioMonitor 2-AF™ (Biotronik SE & Co. KG, Berlin, Germany), Confirm Rx™ (Abbott Laboratories, Lake Bluff, IL, USA) and Reveal LINQ™ (Medtronic plc, Minneapolis, MN, USA)] in patients who have had a cryptogenic stroke and for whom no atrial fibrillation is detected after 24 hours of external electrocardiographic monitoring. Data sources MEDLINE, EMBASE, The Cochrane Library, Database of Abstracts of Reviews of Effects and Health Technology Assessment databases were searched from inception until September 2018. Review methods A systematic review was undertaken. Two reviewers agreed on studies for inclusion and performed quality assessment using the Cochrane Risk of Bias 2.0 tool. Results were discussed narratively because there were insufficient data for synthesis. A two-stage de novo economic model was developed: (1) a short-term patient flow model to identify cryptogenic stroke patients who have had atrial fibrillation detected and been prescribed anticoagulation treatment (rather than remaining on antiplatelet treatment) and (2) a long-term Markov model that captured the lifetime costs and benefits of patients on either anticoagulation or antiplatelet treatment. Results One randomised controlled trial, Cryptogenic Stroke and underlying Atrial Fibrillation (CRYSTAL-AF) (Sanna T, Diener HC, Passman RS, Di Lazzaro V, Bernstein RA, Morillo CA, et al. Cryptogenic stroke and underlying atrial fibrillation. N Engl J Med 2014;370:2478–86), was identified, and no diagnostic test accuracy study was identified. The CRYSTAL-AF trial compared the Reveal™ XT (a Reveal LINQ predecessor) (Medtronic plc) monitor with standard of care monitoring. Twenty-six single-arm observational studies for the Reveal devices were also identified. The only data for BioMonitor 2-AF or Confirm Rx were from mixed population studies supplied by the companies. Atrial fibrillation detection in the CRYSTAL-AF trial was higher with the Reveal XT than with standard monitoring at all time points. By 36 months, atrial fibrillation was detected in 19% of patients with an implantable cardiac monitor and in 2.3% of patients receiving conventional follow-up. The 26 observational studies demonstrated that, even in a cryptogenic stroke population, atrial fibrillation detection rates are highly variable and most cases are asymptomatic; therefore, they probably would not have been picked up without an implantable cardiac monitor. Device-related adverse events, such as pain and infection, were low in all studies. The de novo economic model produced incremental cost effectiveness ratios comparing implantable cardiac monitors with standard of care monitoring to detect atrial fibrillation in cryptogenic stroke patients based on data for the Reveal XT device, which can be related to Reveal LINQ. The BioMonitor 2-AF and Confirm RX were included in the analysis by making a strong assumption of equivalence with Reveal LINQ. The results indicate that implantable cardiac monitors could be considered cost-effective at a £20,000–30,000 threshold. When each device is compared incrementally, BioMonitor 2-AF dominates Reveal LINQ and Confirm RX. Limitations The cost-effectiveness analysis for implantable cardiac monitors is based on a strong assumption of clinical equivalence and should be interpreted with caution. Conclusions All three implantable cardiac monitors could be considered cost-effective at a £20,000–30,000 threshold, compared with standard of care monitoring, for cryptogenic stroke patients with no atrial fibrillation detected after 24 hours of external electrocardiographic monitoring; however, further clinical studies are required to confirm their efficacy in cryptogenic stroke patients. Study registration This study is registered as PROSPERO CRD42018109216. Funding This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 24, No. 5. See the NIHR Journals Library website for further project information.

Funder

Health Technology Assessment programme

Publisher

National Institute for Health Research

Subject

Health Policy

Reference197 articles.

1. Changes in health in England, with analysis by English regions and areas of deprivation, 1990–2013: a systematic analysis for the Global Burden of Disease Study 2013;Newton;Lancet,2015

2. Royal College of Physicians, Sentinel Stroke National Audit Programme (SSNAP). Rising to the Challenge: The Fourth SSNAP Annual Report. 2015. URL: www.strokeaudit.org/Documents/AnnualReport/2016-17-SSNAP-Annual-Report.aspx (accessed 2 January 2019).

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3