Integrated sensor-augmented pump therapy systems [the MiniMed® Paradigm™ Veo system and the Vibe™ and G4® PLATINUM CGM (continuous glucose monitoring) system] for managing blood glucose levels in type 1 diabetes: a systematic review and economic evaluation

Author:

Riemsma Rob1,Corro Ramos Isaac2,Birnie Richard1,Büyükkaramikli Nasuh2,Armstrong Nigel1,Ryder Steve1,Duffy Steven1,Worthy Gill1,Al Maiwenn2,Severens Johan2,Kleijnen Jos13

Affiliation:

1. Kleijnen Systematic Reviews Ltd, York, UK

2. Institute of Health Policy and Management, Erasmus University Rotterdam, Rotterdam, the Netherlands

3. School for Public Health and Primary Care, Maastricht University, Maastricht, the Netherlands

Abstract

BackgroundIn recent years, meters for continuous monitoring of interstitial fluid glucose have been introduced to help people with type 1 diabetes mellitus (T1DM) to achieve better control of their disease.ObjectiveThe objective of this project was to summarise the evidence on the clinical effectiveness and cost-effectiveness of the MiniMed®Paradigm™ Veo system (Medtronic Inc., Northridge, CA, USA) and the Vibe™ (Animas®Corporation, West Chester, PA, USA) and G4®PLATINUM CGM (continuous glucose monitoring) system (Dexcom Inc., San Diego, CA, USA) in comparison with multiple daily insulin injections (MDIs) or continuous subcutaneous insulin infusion (CSII), both with either self-monitoring of blood glucose (SMBG) or CGM, for the management of T1DM in adults and children.Data sourcesA systematic review was conducted in accordance with the principles of the Centre for Reviews and Dissemination guidance and the National Institute for Health and Care Excellence Diagnostic Assessment Programme manual. We searched 14 databases, three trial registries and two conference proceedings from study inception up to September 2014. In addition, reference lists of relevant systematic reviews were checked. In the absence of randomised controlled trials directly comparing Veo or an integrated CSII + CGM system, such as Vibe, with comparator interventions, indirect treatment comparisons were performed if possible.MethodsA commercially available cost-effectiveness model, the IMS Centre for Outcomes Research and Effectiveness diabetes model version 8.5 (IMS Health, Danbury, CT, USA), was used for this assessment. This model is an internet-based, interactive simulation model that predicts the long-term health outcomes and costs associated with the management of T1DM and type 2 diabetes. The model consists of 15 submodels designed to simulate diabetes-related complications, non-specific mortality and costs over time. As the model simulates individual patients over time, it updates risk factors and complications to account for disease progression.ResultsFifty-four publications resulting from 19 studies were included in the review. Overall, the evidence suggests that the Veo system reduces hypoglycaemic events more than other treatments, without any differences in other outcomes, including glycated haemoglobin (HbA1c) levels. We also found significant results in favour of the integrated CSII + CGM system over MDIs with SMBG with regard to HbA1clevels and quality of life. However, the evidence base was poor. The quality of the included studies was generally low, often with only one study comparing treatments in a specific population at a specific follow-up time. In particular, there was only one study comparing Veo with an integrated CSII + CGM system and only one study comparing Veo with a CSII + SMBG system in a mixed population. Cost-effectiveness analyses indicated that MDI + SMBG is the option most likely to be cost-effective, given the current threshold of £30,000 per quality-adjusted life-year gained, whereas integrated CSII + CGM systems and Veo are dominated and extendedly dominated, respectively, by stand-alone, non-integrated CSII with CGM. Scenario analyses did not alter these conclusions. No cost-effectiveness modelling was conducted for children or pregnant women.ConclusionsThe Veo system does appear to be better than the other systems considered at reducing hypoglycaemic events. However, in adults, it is unlikely to be cost-effective. Integrated systems are also generally unlikely to be cost-effective given that stand-alone systems are cheaper and, possibly, no less effective. However, evidence in this regard is generally lacking, in particular for children. Future trials in specific child, adolescent and adult populations should include longer term follow-up and ratings on the European Quality of Life-5 Dimensions scale at various time points with a view to informing improved cost-effectiveness modelling.Study registrationPROSPERO Registration Number CRD42014013764.FundingThe National Institute for Health Research Health Technology Assessment programme.

Funder

Health Technology Assessment programme

Publisher

National Institute for Health Research

Subject

Health Policy

Reference198 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3