Viscoelastic point-of-care testing to assist with the diagnosis, management and monitoring of haemostasis: a systematic review and cost-effectiveness analysis

Author:

Whiting Penny1,Al Maiwenn2,Westwood Marie1,Ramos Isaac Corro2,Ryder Steve1,Armstrong Nigel1,Misso Kate1,Ross Janine1,Severens Johan2,Kleijnen Jos3

Affiliation:

1. Kleijnen Systematic Reviews Ltd, York, UK

2. Institute of Health Policy and Management, Erasmus University Rotterdam, Rotterdam, the Netherlands

3. School for Public Health and Primary Care (CAPHRI), Maastricht University, Maastricht, the Netherlands

Abstract

BackgroundPatients with substantive bleeding usually require transfusion and/or (re-)operation. Red blood cell (RBC) transfusion is independently associated with a greater risk of infection, morbidity, increased hospital stay and mortality. ROTEM (ROTEM®Delta, TEM International GmbH, Munich, Germany;www.rotem.de), TEG (TEG®5000 analyser, Haemonetics Corporation, Niles, IL, USA;www.haemonetics.com) and Sonoclot (Sonoclot®coagulation and platelet function analyser, Sienco Inc., Arvada, CO) are point-of-care viscoelastic (VE) devices that use thromboelastometry to test for haemostasis in whole blood. They have a number of proposed advantages over standard laboratory tests (SLTs): they provide a result much quicker, are able to identify what part of the clotting process is disrupted, and provide information on clot formation over time and fibrinolysis.ObjectivesThis assessment aimed to assess the clinical effectiveness and cost-effectiveness of VE devices to assist with the diagnosis, management and monitoring of haemostasis disorders during and after cardiac surgery, trauma-induced coagulopathy and post-partum haemorrhage (PPH).MethodsSixteen databases were searched to December 2013: MEDLINE (OvidSP), MEDLINE In-Process and Other Non-Indexed Citations and Daily Update (OvidSP), EMBASE (OvidSP), BIOSIS Previews (Web of Knowledge), Science Citation Index (SCI) (Web of Science), Conference Proceedings Citation Index (CPCI-S) (Web of Science), Cochrane Database of Systematic Reviews (CDSR), Cochrane Central Register of Controlled Trials (CENTRAL), Database of Abstracts of Reviews of Effects (DARE), Health Technology Assessment (HTA) database, Latin American and Caribbean Health Sciences Literature (LILACS), International Network of Agencies for Health Technology Assessment (INAHTA), National Institute for Health Research (NIHR) HTA programme, Aggressive Research Intelligence Facility (ARIF), Medion, and the International Prospective Register of Systematic Reviews (PROSPERO). Randomised controlled trials (RCTs) were assessed for quality using the Cochrane Risk of Bias tool. Prediction studies were assessed using QUADAS-2. For RCTs, summary relative risks (RRs) were estimated using random-effects models. Continuous data were summarised narratively. For prediction studies, the odds ratio (OR) was selected as the primary effect estimate. The health-economic analysis considered the costs and quality-adjusted life-years of ROTEM, TEG and Sonoclot compared with SLTs in cardiac surgery and trauma patients. A decision tree was used to take into account short-term complications and longer-term side effects from transfusion. The model assumed a 1-year time horizon.ResultsThirty-one studies (39 publications) were included in the clinical effectiveness review. Eleven RCTs (n = 1089) assessed VE devices in patients undergoing cardiac surgery; six assessed thromboelastography (TEG) and five assessed ROTEM. There was a significant reduction in RBC transfusion [RR 0.88, 95% confidence interval (CI) 0.80 to 0.96; six studies], platelet transfusion (RR 0.72, 95% CI 0.58 to 0.89; six studies) and fresh frozen plasma to transfusion (RR 0.47, 95% CI 0.35 to 0.65; five studies) in VE testing groups compared with control. There were no significant differences between groups in terms of other blood products transfused. Continuous data on blood product use supported these findings. Clinical outcomes did not differ significantly between groups. There were no apparent differences between ROTEM or TEG; none of the RCTs evaluated Sonoclot. There were no data on the clinical effectiveness of VE devices in trauma patients or women with PPH. VE testing was cost-saving and more effective than SLTs. For the cardiac surgery model, the cost-saving was £43 for ROTEM, £79 for TEG and £132 for Sonoclot. For the trauma population, the cost-savings owing to VE testing were more substantial, amounting to per-patient savings of £688 for ROTEM compared with SLTs, £721 for TEG, and £818 for Sonoclot. This finding was entirely dependent on material costs, which are slightly higher for ROTEM. VE testing remained cost-saving following various scenario analyses.ConclusionsVE testing is cost-saving and more effective than SLTs, in both patients undergoing cardiac surgery and trauma patients. However, there were no data on the clinical effectiveness of Sonoclot or of VE devices in trauma patients.Study registrationThis study is registered as PROSPERO CRD42013005623.FundingThe NIHR Health Technology Assessment programme.

Funder

Health Technology Assessment programme

Publisher

National Institute for Health Research

Subject

Health Policy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3