Faecal immunochemical tests to triage patients with lower abdominal symptoms for suspected colorectal cancer referrals in primary care: a systematic review and cost-effectiveness analysis

Author:

Westwood Marie1,Corro Ramos Isaac2,Lang Shona1,Luyendijk Marianne3,Zaim Remziye3,Stirk Lisa1,Al Maiwenn3,Armstrong Nigel1,Kleijnen Jos4

Affiliation:

1. Kleijnen Systematic Reviews Ltd, York, UK

2. Institute for Medical Technology Assessment, Erasmus University Rotterdam, Rotterdam, the Netherlands

3. Institute of Health Policy and Management, Erasmus University Rotterdam, Rotterdam, the Netherlands

4. School for Public Health and Primary Care (Care and Public Health Research Institute), Maastricht University, Maastricht, the Netherlands

Abstract

BackgroundColorectal cancer (CRC) is the third most common cancer in the UK. Presenting symptoms that can be associated with CRC usually have another explanation. Faecal immunochemical tests (FITs) detect blood that is not visible to the naked eye and may help to select patients who are likely to benefit from further investigation.ObjectivesTo assess the effectiveness of FITs [OC-Sensor (Eiken Chemical Co./MAST Diagnostics, Tokyo, Japan), HM-JACKarc (Kyowa Medex/Alpha Laboratories Ltd, Tokyo, Japan), FOB Gold (Sentinel/Sysmex, Sentinel Diagnostics, Milan, Italy), RIDASCREEN Hb or RIDASCREEN Hb/Hp complex (R-Biopharm, Darmstadt, Germany)] for primary care triage of people with low-risk symptoms.MethodsTwenty-four resources were searched to March 2016. Review methods followed published guidelines. Summary estimates were calculated using a bivariate model or a random-effects logistic regression model. The cost-effectiveness analysis considered long-term costs and quality-adjusted life-years (QALYs) that were associated with different faecal occult blood tests and direct colonoscopy referral. Modelling comprised a diagnostic decision model, a Markov model for long-term costs and QALYs that were associated with CRC treatment and progression, and a Markov model for QALYs that were associated with no CRC.ResultsWe included 10 studies. Using a single sample and 10 µg Hb/g faeces threshold, sensitivity estimates for OC-Sensor [92.1%, 95% confidence interval (CI) 86.9% to 95.3%] and HM-JACKarc (100%, 95% CI 71.5% to 100%) indicated that both may be useful to rule out CRC. Specificity estimates were 85.8% (95% CI 78.3% to 91.0%) and 76.6% (95% CI 72.6% to 80.3%). Triage using FITs could rule out CRC and avoid colonoscopy in approximately 75% of symptomatic patients. Data from our systematic review suggest that 22.5–93% of patients with a positive FIT and no CRC have other significant bowel pathologies. The results of the base-case analysis suggested minimal difference in QALYs between all of the strategies; no triage (referral straight to colonoscopy) is the most expensive. Faecal immunochemical testing was cost-effective (cheaper and more, or only slightly less, effective) compared with no triage. Faecal immunochemical testing was more effective and costly than guaiac faecal occult blood testing, but remained cost-effective at a threshold incremental cost-effectiveness ratio of £30,000. The results of scenario analyses did not differ substantively from the base-case. Results were better for faecal immunochemical testing when accuracy of the guaiac faecal occult blood test (gFOBT) was based on studies that were more representative of the correct population.LimitationsOnly one included study evaluated faecal immunochemical testing in primary care; however, all of the other studies evaluated faecal immunochemical testing at the point of referral. Further, validation data for the Faecal haemoglobin, Age and Sex Test (FAST) score, which includes faecal immunochemical testing, showed no significant difference in performance between primary and secondary care. There were insufficient data to adequately assess FOB Gold, RIDASCREEN Hb or RIDASCREEN Hb/Hp complex. No study compared FIT assays, or FIT assays versus gFOBT; all of the data included in this assessment refer to the clinical effectiveness of individual FIT methods andnottheir comparative effectiveness.ConclusionsFaecal immunochemical testing is likely to be a clinically effective and cost-effective strategy for triaging people who are presenting, in primary care settings, with lower abdominal symptoms and who are at low risk for CRC. Further research is required to confirm the effectiveness of faecal immunochemical testing in primary care practice and to compare the performance of different FIT assays.Study registrationThis study is registered as PROSPERO CRD42016037723.FundingThe National Institute for Health Research Health Technology Assessment programme.

Funder

Health Technology Assessment programme

Publisher

National Institute for Health Research

Subject

Health Policy

Reference148 articles.

1. Increased uptake and improved outcomes of bowel cancer screening with a faecal immunochemical test: results from a pilot study within the national screening programme in England [published online ahead of print June 7 2016];Moss;Gut,2016

2. European guidelines for quality assurance in colorectal cancer screening and diagnosis. First Edition: Faecal occult blood testing;Halloran;Endoscopy,2012

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3