The clinical effectiveness and cost-effectiveness of heated humidified high-flow nasal cannula compared with usual care for preterm infants: systematic review and economic evaluation

Author:

Fleeman Nigel1,Mahon James2,Bates Vickie1,Dickson Rumona1,Dundar Yenal1,Dwan Kerry13,Ellis Laura4,Kotas Eleanor1,Richardson Marty1,Shah Prakesh5,Shaw Ben NJ6

Affiliation:

1. Liverpool Reviews and Implementation Group, University of Liverpool, Liverpool, UK

2. Coldingham Analytical Services, Berwickshire, UK

3. Cochrane Editorial Unit, Cochrane Collaboration, London, UK

4. Patient representative (parent of premature infants)

5. Departments of Paediatrics and Institute of Health Policy, Management and Evaluation, University of Toronto, Mount Sinai Hospital, Toronto, ON, Canada

6. Neonatal Unit, Liverpool Women’s NHS Foundation Trust, Liverpool, UK

Abstract

BackgroundRespiratory problems are one of the most common causes of morbidity in preterm infants and may be treated with several modalities for respiratory support such as nasal continuous positive airway pressure (NCPAP) or nasal intermittent positive-pressure ventilation. The heated humidified high-flow nasal cannula (HHHFNC) is gaining popularity in clinical practice.ObjectivesTo address the clinical effectiveness of HHHFNC compared with usual care for preterm infants we systematically reviewed the evidence of HHHFNC with usual care following ventilation (the primary analysis) and with no prior ventilation (the secondary analysis). The primary outcome was treatment failure defined as the need for reintubation (primary analysis) or intubation (secondary analysis). We also aimed to assess the cost-effectiveness of HHHFNC compared with usual care if evidence permitted.Data sourcesThe following databases were searched: MEDLINE (2000 to 12 January 2015), EMBASE (2000 to 12 January 2015), The Cochrane Library (issue 1, 2015), ISI Web of Science (2000 to 12 January 2015), PubMed (1 March 2014 to 12 January 2015) and seven trial and research registers. Bibliographies of retrieved citations were also examined.Review methodsTwo reviewers independently screened all titles and abstracts to identify potentially relevant studies for inclusion in the review. Full-text copies were assessed independently. Data were extracted and assessed for risk of bias. Summary statistics were extracted for each outcome and, when possible, data were pooled. A meta-analysis was only conducted for the primary analysis, using fixed-effects models. An economic evaluation was planned.ResultsClinical evidence was derived from seven randomised controlled trials (RCTs): four RCTs for the primary analysis and three RCTs for the secondary analysis. Meta-analysis found that only for nasal trauma leading to a change of treatment was there a statistically significant difference, favouring HHHFNC over NCPAP [risk ratio (RR) 0.21, 95% confidence interval (CI) 0.10 to 0.42]. For the following outcomes, there were no statistically significant differences between arms: treatment failure (reintubation < 7 days; RR 0.76, 95% CI 0.54 to 1.09), bronchopulmonary dysplasia (RR 0.92, 95% CI 0.72 to 1.17), death (RR 0.56, 95% CI 0.22 to 1.44), pneumothorax (RR 0.33, 95% CI 0.03 to 3.12), intraventricular haemorrhage (grade ≥ 3; RR 0.41, 95% CI 0.15 to 1.15), necrotising enterocolitis (RR 0.41, 95% CI 0.15 to 1.14), apnoea (RR 1.08, 95% CI 0.74 to 1.57) and acidosis (RR 1.16, 95% CI 0.38 to 3.58). With no evidence to support the superiority of HHHFNC over NCPAP, a cost-minimisation analysis was undertaken, the results suggesting HHHFNC to be less costly than NCPAP. However, this finding is sensitive to the lifespan of equipment and the cost differential of consumables.LimitationsThere is a lack of published RCTs of relatively large-sized populations comparing HHHFNC with usual care; this is particularly true for preterm infants who had received no prior ventilation.ConclusionsThere is a lack of convincing evidence suggesting that HHHFNC is superior or inferior to usual care, in particular NCPAP. There is also uncertainty regarding whether or not HHHFNC can be considered cost-effective. Further evidence comparing HHHFNC with usual care is required.Study registrationThis review is registered as PROSPERO CRD42015015978.FundingThe National Institute for Health Research Health Technology Assessment programme.

Funder

Health Technology Assessment programme

Publisher

National Institute for Health Research

Subject

Health Policy

Cited by 23 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3