Urinary Estrone Conjugate and Pregnanediol 3-Glucuronide Enzyme Immunoassays for Population Research

Author:

O’Connor Kathleen A1,Brindle Eleanor1,Holman Darryl J1,Klein Nancy A2,Soules Michael R2,Campbell Kenneth L3,Kohen Fortüne4,Munro Coralie J5,Shofer Jane B6,Lasley Bill L7,Wood James W89

Affiliation:

1. Department of Anthropology and Center for Studies in Demography and Ecology

2. Department of Obstetrics and Gynecology, and

3. Department of Biology, University of Massachusetts, Boston, MA 02125

4. Department of Biological Regulation, Weizmann Institute of Science, Rehovet 76100, Israel

5. Population Health and Reproduction and

6. Department of Medicine, Division of Metabolism, Endocrinology, and Nutrition, University of Washington, Seattle WA 98195

7. Obstetrics and Gynecology, University of California, Davis, CA 95616

8. Department of Anthropology and Population Research Institute, Pennsylvania State University, University Park, PA 16802

9. Departments of

Abstract

Abstract Background: Monitoring of reproductive steroid hormones at the population level requires frequent measurements, hormones or metabolites that remain stable under less than ideal collection and storage conditions, a long-term supply of antibodies, and assays useful for a range of populations. We developed enzyme immunoassays for urinary pregnanediol 3-glucuronide (PDG) and estrone conjugates (E1Cs) that meet these criteria. Methods: Enzyme immunoassays based on monoclonal antibodies were evaluated for specificity, detection limit, parallelism, recovery, and imprecision. Paired urine and serum specimens were analyzed throughout menstrual cycles of 30 US women. Assay application in different populations was examined with 23 US and 42 Bangladeshi specimens. Metabolite stability in urine was evaluated for 0–8 days at room temperature and for 0–10 freeze-thaw cycles. Results: Recoveries were 108% for the PDG assay and 105% for the E1C assay. Serially diluted specimens exhibited parallelism with calibration curves in both assays. Inter- and intraassay CVs were <11%. Urinary and serum concentrations were highly correlated: r = 0.93 for E1C–estradiol; r = 0.98 for PDG–progesterone. All Bangladeshi and US specimens were above detection limits (PDG, 21 nmol/L; E1C, 0.27 nmol/L). Bangladeshi women had lower follicular phase PDG and lower luteal phase PDG and E1Cs than US women. Stability experiments showed a maximum decrease in concentration for each metabolite of <4% per day at room temperature and no significant decrease associated with number of freeze-thaw cycles. Conclusions: These enzyme immunoassays can be used for the field conditions and population variation in hormone metabolite concentrations encountered in cross-cultural research.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3