Diagnostic Accuracy of Holotranscobalamin, Methylmalonic Acid, Serum Cobalamin, and Other Indicators of Tissue Vitamin B12 Status in the Elderly

Author:

Valente Edward1,Scott John M2,Ueland Per-Magne3,Cunningham Conal4,Casey Miriam4,Molloy Anne M2

Affiliation:

1. Axis-Shield Diagnostics, Dundee, UK

2. School of Biochemistry and Immunology, Trinity College Dublin, Dublin, Republic of Ireland

3. Section for Pharmacology, Institute of Medicine, University of Bergen, and Laboratory of Clinical Biochemistry, Haukeland University Hospital, Bergen, Norway

4. Mercers Institute for Research on Aging, St James Hospital, Dublin, Republic of Ireland

Abstract

BACKGROUND Vitamin B12 deficiency is common among the elderly, and early detection is clinically important. However, clinical signs and symptoms have limited diagnostic accuracy and there is no accepted reference test method. METHODS In elderly subjects (n = 700; age range 63–97 years), we investigated the ability of serum cobalamin, holotranscobalamin (holoTC), total homocysteine (tHcy), methylmalonic acid (MMA), serum and erythrocyte folate, and other hematologic variables to discriminate cobalamin deficiency, defined as red blood cell cobalamin <33 pmol/L. RESULTS Serum holoTC was the best predictor, with area under the ROC curve (95% CI) 0.90 (0.86–0.93), and this was significantly better (P ≤ 0.0002) than the next best predictors; serum cobalamin, 0.80 (0.75–0.85), and MMA, 0.78 (0.72–0.83). For these 3 analytes, we constructed a 3-zone partition of positive and negative zones and a deliberate indeterminate zone between. The boundaries were values of each test that resulted in a posttest probability of deficiency of 60% and a posttest probability of no deficiency of 98%. The proportion of indeterminate observations for holoTC, cobalamin, and MMA was 14%, 45%, and 50%, respectively. Within the holoTC indeterminate zone (defined as 20–30 pmol/L), discriminant analysis selected only erythrocyte folate, which correctly allocated 65% (58/89) of the observations. Renal dysfunction compromised the diagnostic accuracy of MMA but not holoTC or serum cobalamin. CONCLUSIONS This study supports the use of holoTC as the first-line diagnostic procedure for vitamin B12 status.

Funder

Fisheries and Food and the Health Research Board

Food for Health Research Initiative

Axis-Shield Diagnostics

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3